Show simple item record

dc.contributor.authorAdrian Martinez, Silvia
dc.contributor.authorAgeron, M.
dc.contributor.authorAiello, S
dc.contributor.authorAlbert, A.
dc.contributor.authorAmeli, F
dc.contributor.authorAnassontzis, E.G.
dc.contributor.authorAndré, Michel
dc.contributor.otherCentre Tecnològic de Vilanova i la Geltrú
dc.date.accessioned2017-03-07T16:34:37Z
dc.date.available2017-03-07T16:34:37Z
dc.date.issued2016-12-19
dc.identifier.citationAdrian-Martinez, S., Ageron, M., Aiello, S., Albert, A., Ameli, F., Anassontzis, E., Andre, M., E. A. A method to stabilise the performance of negatively fed KM3NeT photomultipliers. "Journal of instrumentation", 19 Desembre 2016, vol. 11.
dc.identifier.issn1748-0221
dc.identifier.urihttp://hdl.handle.net/2117/102079
dc.description.abstractThe KM3NeT research infrastructure, currently under construction in the Mediterranean Sea, will host neutrino telescopes for the identification of neutrino sources in the Universe and for studies of the neutrino mass hierarchy. These telescopes will house hundreds of thousands of photomultiplier tubes that will have to be operated in a stable and reliable fashion. In this context, the stability of the dark counts has been investigated for photomultiplier tubes with negative high voltage on the photocathode and held in insulating support structures made of 3D printed nylon material. Small gaps between the rigid support structure and the photomultiplier tubes in the presence of electric fields can lead to discharges that produce dark count rates that are highly variable. A solution was found by applying the same insulating varnish as used for the high voltage bases directly to the outside of the photomultiplier tubes. This transparent conformal coating provides a convenient and inexpensive method of insulation.
dc.language.isoeng
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Física
dc.subject.lcshNeutrinos
dc.subject.lcshNeutrino astrophysics
dc.subject.lcshOptical detectors
dc.titleA method to stabilise the performance of negatively fed KM3NeT photomultipliers
dc.typeArticle
dc.subject.lemacDetectors òptics
dc.subject.lemacPartícules (Física nuclear)
dc.subject.lemacNeutrins
dc.contributor.groupUniversitat Politècnica de Catalunya. LAB - Laboratori d'Aplicacions Bioacústiques
dc.identifier.doi10.1088/1748-0221/11/12/P12014
dc.relation.publisherversionhttp://iopscience.iop.org/article/10.1088/1748-0221/11/12/P12014
dc.rights.accessOpen Access
local.identifier.drac19668351
dc.description.versionPostprint (published version)
local.citation.authorAdrian-Martinez, S.; Ageron, M.; Aiello, S.; Albert, A.; Ameli, F.; Anassontzis, E.; Andre, M.; et al.,
local.citation.publicationNameJournal of instrumentation
local.citation.volume11


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record