Mostra el registre d'ítem simple

dc.contributor.authorRoslan, Nurul Fazlin
dc.contributor.authorSuul, Jon Are
dc.contributor.authorLuna Alloza, Álvaro
dc.contributor.authorRocabert Delgado, Joan
dc.contributor.authorCandela García, José Ignacio
dc.contributor.authorRodríguez Cortés, Pedro
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica
dc.date.accessioned2017-03-03T09:18:11Z
dc.date.available2017-03-03T09:18:11Z
dc.date.issued2016
dc.identifier.citationRoslan, N., Suul, J., Luna, A., Rocabert, J., Candela, J., Rodriguez, P. A comparative study of methods for estimating virtual flux at the point of common coupling in grid connected voltage source converters with LCL filter. A: IEEE Energy Conversion Congress and Exposition. "ECCE 2016: IEEE Energy Conversion Congress and Exposition: Milwaukee, USA: Sept. 18-22, 2016". Milwaukee: 2016, p. 1-6.
dc.identifier.urihttp://hdl.handle.net/2117/101896
dc.description.abstractGrid connected Voltage Source Converters (VSCs) with LCL filters usually have voltage measurements at the filter capacitors, while it can be important to control the active or reactive power injection at the grid-side of the LCL filter, for instance at a Point of Common Coupling (PCC). Synchronization to the PCC voltage can be obtained by Virtual Flux (VF) estimation, which can also allow for voltage sensor-less operation of VSCs. This paper is presenting a comparative evaluation of methods for estimating the VF at the PCC, considering a VSC connected to the grid through an LCL filter with a Proportional Resonant (PR) controller as the inner current control loop. The VF estimation is achieved by using frequency adaptive dual SOGI-QSGs (DSOGI-VF). The Frequency Locked Loop (FLL) is used in order to keep the positive and negative sequence (PNS) VF estimation inherently frequency adaptive. Three different methods are considered for obtaining the capacitor current needed for estimating the VF at the grid side of the LCL filter which are based on fully estimation by using the voltage sensor-less method, by estimating the capacitor current from the measured voltage or by using additional capacitor current sensors. The results have been compared and validated by simulation studies.
dc.format.extent6 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica::Electrònica de potència::Convertidors de corrent elèctric
dc.subjectÀrees temàtiques de la UPC::Energies::Energia elèctrica::Automatització i control de l'energia elèctrica
dc.subject.lcshElectric current converters
dc.subject.lcshElectric filters
dc.subject.lcshPhase-locked loops
dc.subject.othervirtual flux estimation
dc.subject.othervoltage source converter
dc.subject.otherproportional resonant current controller
dc.subject.otherLCL-filter
dc.titleA comparative study of methods for estimating virtual flux at the point of common coupling in grid connected voltage source converters with LCL filter
dc.typeConference report
dc.subject.lemacConvertidors de corrent elèctric
dc.subject.lemacFiltres elèctrics
dc.subject.lemacLlaços de seguiment de fase
dc.contributor.groupUniversitat Politècnica de Catalunya. SEER - Sistemes Elèctrics d'Energia Renovable
dc.identifier.doi10.1109/ECCE.2016.7854660
dc.description.peerreviewedPeer Reviewed
dc.rights.accessOpen Access
local.identifier.drac19742534
dc.description.versionPostprint (author's final draft)
local.citation.authorRoslan, N.; Suul, J.; Luna, A.; Rocabert, J.; Candela, J.; Rodriguez, P.
local.citation.contributorIEEE Energy Conversion Congress and Exposition
local.citation.pubplaceMilwaukee
local.citation.publicationNameECCE 2016: IEEE Energy Conversion Congress and Exposition: Milwaukee, USA: Sept. 18-22, 2016
local.citation.startingPage1
local.citation.endingPage6


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple