Mostra el registre d'ítem simple

dc.contributor.authorPelà, Luca
dc.contributor.authorKasioumi, Konstantina
dc.contributor.authorRoca Fabregat, Pedro
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental
dc.date.accessioned2017-02-14T15:36:22Z
dc.date.available2019-05-01T00:31:02Z
dc.date.issued2017-04
dc.identifier.citationPela, L., Kasioumi, K., Roca, P. Experimental evaluation of the shear strength of aerial lime mortar brickwork by standard tests on triplets and non-standard tests on core samples. "Engineering structures", Abril 2017, vol. 136, p. 441-453.
dc.identifier.issn0141-0296
dc.identifier.urihttp://hdl.handle.net/2117/101009
dc.description.abstractThis paper presents the results of an experimental program carried out in the laboratory to evaluate the shear strength of aerial lime mortar brickwork. Masonry triplets and walls were tested after one year from their construction by adopting two different testing methods. The first approach consisted in the shear tests of masonry triplets, whereas the second technique was based on core drilling from walls of 90 mm diameter cylindrical specimens to be subjected to Brazilian tests with varying inclination of the diametric mortar joint. The first method is more adequate to characterize new masonry, whilst the second one is a suitable MDT procedure for the analysis of existing structures. The experimental results from standard and non-standard tests were properly investigated in order to obtain the shear failure envelope of the bond interface and mortar joint. The comparisons between the different tests and their interpretative theories show the possibilities of the novel non-standard testing method for the evaluation of the shear strength of structures of the built cultural heritage.
dc.format.extent13 p.
dc.language.isoeng
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Materials i estructures
dc.subject.lcshBrickwork, concrete, and masonry
dc.subject.otherMasonry
dc.subject.otherTriplets
dc.subject.otherCoring
dc.subject.otherDouble Punch Test
dc.subject.otherBrazilian test
dc.subject.otherMinor Destructive Testing (MDT)
dc.subject.otherMohr-Coulomb criterion
dc.subject.otherFriction
dc.subject.otherCohesion
dc.subject.otherBond interface
dc.titleExperimental evaluation of the shear strength of aerial lime mortar brickwork by standard tests on triplets and non-standard tests on core samples
dc.typeArticle
dc.subject.lemacEstructures de murs
dc.contributor.groupUniversitat Politècnica de Catalunya. ATEM - Anàlisi i Tecnologia d'Estructures i Materials
dc.identifier.doi10.1016/j.engstruct.2017.01.028
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S0141029616307581
dc.rights.accessOpen Access
local.identifier.drac19508281
dc.description.versionPostprint (author's final draft)
local.citation.authorPela, L.; Kasioumi, K.; Roca, P.
local.citation.publicationNameEngineering structures
local.citation.volume136
local.citation.startingPage441
local.citation.endingPage453