dc.identifier.citationPages, N., Gibert, O., Bernat, X., Cortina, J. Removal of dissolved organic carbon and bromide by a hybrid MIEX-ultrafiltration system: Insight into the behaviour of organic fractions. "Chemical engineering journal", 2016, vol. 312, p. 59-67.
dc.identifier.issn0300-9467
dc.identifier.urihttp://hdl.handle.net/2117/100413
dc.description.abstractDissolved organic carbon (DOC) and bromide (Br-) are principal precursors in the formation of halogenated disinfection by-products resulting from chlorination of drinking water. Their effective removal from water represents, thus, one of the main challenges faced by drinking water treatment plants worldwide. The objective of this study was to evaluate the performance of a pilot-scale hybrid system based on the patented magnetic ion-exchange resin (MIEX) combined with ultrafiltration (UF) in the removal of DOC and Br- from water. Two different doses of MIEX (1 mL/L and 3 mL/L) were applied and compared. Samples of feed water, UF permeate and tank solution were regularly collected to assess the system performance in terms of removal of DOC and Br-. DOC was characterised by high-performance size-exclusion chromatography (HPSEC) and 3D-fluorescence excitation-emission matrix (FEEM) to identify which organic fractions were preferentially removed by the MIEX/UF process. Results demonstrated that the hybrid MIEX/UF system was able to remove DOC and Br- from water. The evolution and extent of these removals depended on the MIEX dose applied, with percentage removals clearly increasing when the MIEX dose was increased from 1 mL/L to 3 mL/L. MIEX exhibited higher affinity toward DOC than toward Br-. Saturation of MIEX toward Br- was achieved short after the start of the experiment, while removal of DOC persisted until the end of the experiment. Fractionation of DOC by HPSEC indicated that the highest molecular weight fraction was mainly removed by size-exclusion by the UF membrane, while lower molecular weight fractions seemed to be better removed by ion-exchange on the MIEX resin. FEEM analysis revealed a poor affinity of MIEX toward microbial by-products, whereas fulvic and humic acid-like material were the most retained by MIEX.
dc.format.extent9 p.
dc.language.isoeng
dc.publisherElsevier
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria química
dc.subject.lcshUltrafiltration
dc.subject.lcshSewage--Purification
dc.subject.otherMIEX
dc.subject.otherUltrafiltration
dc.subject.otherDissolved organic carbon
dc.subject.otherBromide
dc.subject.otherHPSEC
dc.subject.otherFEEM
dc.titleRemoval of dissolved organic carbon and bromide by a hybrid MIEX-ultrafiltration system: Insight into the behaviour of organic fractions
dc.typeArticle
dc.subject.lemacUltrafiltració
dc.subject.lemacAigües residuals -- Depuració
dc.subject.lemacGomes i resines
dc.contributor.groupUniversitat Politècnica de Catalunya. SETRI - Grup de Tècniques de Separació i Tractament de Residus Industrials
dc.identifier.doi10.1016/j.cej.2016.11.120
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S1385894716316904
dc.rights.accessOpen Access
local.identifier.drac19310000
dc.description.versionPostprint (author's final draft)
local.citation.authorPages, N.; Gibert, O.; Bernat, X.; Cortina, J.
local.citation.publicationNameChemical engineering journal
local.citation.volume312
local.citation.startingPage59
local.citation.endingPage67


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record