Mostra el registre d'ítem simple

dc.contributor.authorGonzàlez Corominas, Andreu
dc.contributor.authorEtxeberria Larrañaga, Miren
dc.contributor.authorFernández Pérez, Ignasi
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental
dc.date.accessioned2017-01-25T19:21:17Z
dc.date.available2018-03-01T01:30:21Z
dc.date.issued2017-02
dc.identifier.citationGonzalez, A., Etxeberria, M., Fernandez, I. Structural behaviour of prestressed concrete sleepers produced with high performance recycled aggregate concrete. "Materials and structures", Febrer 2017, vol. 50, p. 1-14.
dc.identifier.issn1359-5997
dc.identifier.urihttp://hdl.handle.net/2117/100081
dc.descriptionThe final publication is available at Springer via http://dx.doi.org/10.1617/s11527-016-0966-6
dc.description.abstractA comparative analysis of the structural behaviour of prestressed concrete sleepers made with high performance concrete (HPC) and high performance recycled aggregate concrete (HPRAC) is presented in this study. Two types of HPRAC sleepers were tested, using 50 and 100% of recycled concrete aggregate (RCA) in replacement of coarse natural aggregates. The RCA employed in this research was sourced from crushing rejected HPC sleepers. The aim of this study was to determine through analysis if the HPRAC sleepers’ behaviour fulfilled the European minimum requirements standards for prestressed concrete sleepers and compare their experimental behaviour with that of the HPC sleepers. The three types of prestressed concrete sleepers were subjected to static load tests at rail-seat and centre section (positive and negative load). In the centre section tests a comparative study between the experimental results and the proposed values of four assessment methods of ultimate capacity was carried out. Dynamic load and fatigue tests were also performed at the rail-seat section. The HPRACs and HPC sleepers met all the structural requirements for prestressed concrete sleepers. The experimental results determined the satisfactory performance of the HPRAC-50 and the HPRAC-100, which was very similar to that of the HPC sleepers. The load–strain behaviour recorded via the use of strain gauges on the prestressing bars revealed slightly higher stiffness of the HPC sleepers. The values obtained from the four assessment methods of ultimate capacity were also accurate when applied to HPRAC.
dc.format.extent14 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó
dc.subject.lcshConcrete footings
dc.subject.otherRecycled aggregate concrete
dc.subject.otherHigh performance concrete
dc.subject.otherSleeperStructural prestressed concrete
dc.subject.otherRailway sustainability
dc.titleStructural behaviour of prestressed concrete sleepers produced with high performance recycled aggregate concrete
dc.typeArticle
dc.subject.lemacFonaments
dc.subject.lemacFormigó reciclat
dc.contributor.groupUniversitat Politècnica de Catalunya. ATEM - Anàlisi i Tecnologia d'Estructures i Materials
dc.identifier.doi10.1617/s11527-016-0966-6
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://link.springer.com/article/10.1617%2Fs11527-016-0966-6
dc.rights.accessOpen Access
local.identifier.drac19266383
dc.description.versionPostprint (author's final draft)
local.citation.authorGonzalez, A.; Etxeberria, M.; Fernandez, I.
local.citation.publicationNameMaterials and structures
local.citation.volume50
local.citation.startingPage1
local.citation.endingPage14


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple