Structural behaviour of prestressed concrete sleepers produced with high performance recycled aggregate concrete
dc.contributor.author | Gonzàlez Corominas, Andreu |
dc.contributor.author | Etxeberria Larrañaga, Miren |
dc.contributor.author | Fernández Pérez, Ignasi |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental |
dc.date.accessioned | 2017-01-25T19:21:17Z |
dc.date.available | 2018-03-01T01:30:21Z |
dc.date.issued | 2017-02 |
dc.identifier.citation | Gonzalez, A., Etxeberria, M., Fernandez, I. Structural behaviour of prestressed concrete sleepers produced with high performance recycled aggregate concrete. "Materials and structures", Febrer 2017, vol. 50, p. 1-14. |
dc.identifier.issn | 1359-5997 |
dc.identifier.uri | http://hdl.handle.net/2117/100081 |
dc.description | The final publication is available at Springer via http://dx.doi.org/10.1617/s11527-016-0966-6 |
dc.description.abstract | A comparative analysis of the structural behaviour of prestressed concrete sleepers made with high performance concrete (HPC) and high performance recycled aggregate concrete (HPRAC) is presented in this study. Two types of HPRAC sleepers were tested, using 50 and 100% of recycled concrete aggregate (RCA) in replacement of coarse natural aggregates. The RCA employed in this research was sourced from crushing rejected HPC sleepers. The aim of this study was to determine through analysis if the HPRAC sleepers’ behaviour fulfilled the European minimum requirements standards for prestressed concrete sleepers and compare their experimental behaviour with that of the HPC sleepers. The three types of prestressed concrete sleepers were subjected to static load tests at rail-seat and centre section (positive and negative load). In the centre section tests a comparative study between the experimental results and the proposed values of four assessment methods of ultimate capacity was carried out. Dynamic load and fatigue tests were also performed at the rail-seat section. The HPRACs and HPC sleepers met all the structural requirements for prestressed concrete sleepers. The experimental results determined the satisfactory performance of the HPRAC-50 and the HPRAC-100, which was very similar to that of the HPC sleepers. The load–strain behaviour recorded via the use of strain gauges on the prestressing bars revealed slightly higher stiffness of the HPC sleepers. The values obtained from the four assessment methods of ultimate capacity were also accurate when applied to HPRAC. |
dc.format.extent | 14 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó |
dc.subject.lcsh | Concrete footings |
dc.subject.other | Recycled aggregate concrete |
dc.subject.other | High performance concrete |
dc.subject.other | SleeperStructural prestressed concrete |
dc.subject.other | Railway sustainability |
dc.title | Structural behaviour of prestressed concrete sleepers produced with high performance recycled aggregate concrete |
dc.type | Article |
dc.subject.lemac | Fonaments |
dc.subject.lemac | Formigó reciclat |
dc.contributor.group | Universitat Politècnica de Catalunya. ATEM - Anàlisi i Tecnologia d'Estructures i Materials |
dc.identifier.doi | 10.1617/s11527-016-0966-6 |
dc.description.peerreviewed | Peer Reviewed |
dc.relation.publisherversion | http://link.springer.com/article/10.1617%2Fs11527-016-0966-6 |
dc.rights.access | Open Access |
local.identifier.drac | 19266383 |
dc.description.version | Postprint (author's final draft) |
local.citation.author | Gonzalez, A.; Etxeberria, M.; Fernandez, I. |
local.citation.publicationName | Materials and structures |
local.citation.volume | 50 |
local.citation.startingPage | 1 |
local.citation.endingPage | 14 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [3.002]
-
Articles de revista [360]