Abstract
A method for improve the reliability in a gas liquefied plant using Hotelling
T2 is showed in this paper. The stationery work in this manufacture facilities
during a few moths in a year involve a heavy duty service of gas diesel engines and
ammonia gas plant for processing the methane gas and extract the condensate
fluid of it. Then, a predictive maintenance plan is necessary to prevent a possible
malfunction or shut down of the plant and avoid an operational cost increased.
We are just sampling the signals from the plant when its working in optimal condition
and then we will compare the next incoming data from the machinery versus
the previous historical data set. An statistical process control algorithm Hotelling T2
based for monitoring the condition of gas engines and ammonia gas plant will be
implemented.
CitacióGómez Solaetxe, Miguel Ángel; Larrabe Barrena, Juan Luis. Improve reliability using hotelling T2 technique in a liquefied natural gas plant. "Instrumentation Viewpoint", 15 Març 2010, núm. 8, p. 63-64.