dc.description.abstract | The objective of this final thesis project was to study and test a 3,3V LiFePo4 battery in outer space conditions to be able to determine its working range, its limitations and its problems.
To do so a measuring set-up to read and estimate the capacity of a battery was built and programmed. Then the LiFePo4 battery was tested at different temperatures between -20°C and 40°C in a vacuum chamber at a pressure under 100 microbars.
The results showed that the battery can still operate properly at temperatures as low as -20°C.
However a reduction of the capacity at low temperatures was observed: The battery's capacity at -20°C was 62% lower than the one at 20°C. The battery fully recovered its capacity after returning back to the nominal working range (20°C), and its performance barely changed thorough the whole range of temperatures studied. |
dc.language.iso | eng |
dc.publisher | Universitat Politècnica de Catalunya |
dc.publisher | Univerza v Mariboru |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Spain |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Energies::Tecnologia energètica::Emmagatzematge i transport de l’energia |
dc.subject | Àrees temàtiques de la UPC::Física |
dc.subject.lcsh | Lithium cells |
dc.title | Thermal analysis of a LiFePo4 Battery |
dc.type | Bachelor thesis |
dc.subject.lemac | Piles de liti |
dc.rights.access | Open Access |
dc.audience.educationlevel | Grau |
dc.audience.mediator | Escola Tècnica Superior d'Enginyeria Industrial de Barcelona |
dc.contributor.covenantee | Univerza v Mariboru |
dc.description.mobility | Outgoing |