Mostra el registre d'ítem simple

dc.contributorDuch Guillen, María Amor
dc.contributor.authorMercadal Cavaller, Borja
dc.contributor.otherUniversitat Politècnica de Catalunya. Institut de Tècniques Energètiques
dc.date.accessioned2015-06-11T17:43:03Z
dc.date.available2015-06-16T08:30:15Z
dc.date.issued2014-09
dc.identifier.urihttp://hdl.handle.net/2099.1/26199
dc.description.abstractCancer is one of the leading causes of death around the world and the number of patients is expected to increase in the next years. Most of the cancer patients are treated with radiotherapy for at least a part of their treatment. The success of a radiation therapy treatment lies on its correct planning and the accurate prediction of dose distribution in the patient. These dose distributions are generated using treatment planning systems. Analytical algorithms are commonly used despite more accurate results can be achieved using Monte Carlo based algorithms due to the long calculation times required by them. In 2013 a new Monte Carlo based algorithm, PRIMO, was developed. In this program, based on PENELOPE, several variance reduction techniques have been included in order to speed up the calculations as well as a graphical user interface has been designed to make it user friendly. This work will help to validate the simulation code PRIMO. The validation of a treatment planning algorithm involves many different tests, among them, a basic validation of computed doses compared to measurements in water, as well as the verification of its dosimetric accuracy in complex situations. The aim of this work is to investigate the performance of the PRIMO code, in particular to study its dosimetric accuracy in complex situations such as the presence of materials different than water (lung and bone) and when computing the dose within the first millimeters of the patient. This aim was translated into a set of computational experiments performed on simple geometrical phantoms as well as on computerized tomography images. Results showed that the algorithm allows to obtain accurate results in water phantoms, as well as in regions susceptible to errors like the build up region and regions with material heterogeneities.
dc.language.isoeng
dc.publisherUniversitat Politècnica de Catalunya
dc.subjectÀrees temàtiques de la UPC::Ciències de la salut::Medicina
dc.subjectÀrees temàtiques de la UPC::Física::Electromagnetisme::Radioones i microones
dc.subjectÀrees temàtiques de la UPC::Matemàtiques i estadística::Investigació operativa::Simulació
dc.subject.lcshRadiation -- Dosimetry
dc.subject.lcshRadiation -- Dosage -- Simulation methods
dc.subject.lcshRadiotherapy
dc.subject.lcshMonte Carlo method
dc.titleValidación del código PRIMO de simulación para radioterapia externa
dc.title.alternativeValidation of the simulation code PRIMO for external radiotherapy
dc.typeMaster thesis
dc.subject.lemacRadiació -- Dosimetria
dc.subject.lemacRadiació -- Dosificació -- Mètodes de simulació
dc.subject.lemacRadioteràpia
dc.subject.lemacMontecarlo, Mètode de
dc.rights.accessOpen Access
dc.audience.educationlevelMàster
dc.audience.mediatorEscola Tècnica Superior d'Enginyeria Industrial de Barcelona
dc.audience.degreeMÀSTER UNIVERSITARI EN ENGINYERIA BIOMÈDICA (Pla 2009)


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple