Fetal ECG extraction from maternal ECG using attention-based cycleGAN
| dc.contributor.author | Mohebbian, Mohammad Reza |
| dc.contributor.author | Vedaei, Seyed Shahim |
| dc.contributor.author | Wahid, Khan A. |
| dc.contributor.author | Dinh, Anh |
| dc.contributor.author | Marateb, Hamid Reza |
| dc.contributor.author | Tavakolian, Kouhyar |
| dc.contributor.group | Universitat Politècnica de Catalunya. BIOART - BIOsignal Analysis for Rehabilitation and Therapy |
| dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial |
| dc.date.accessioned | 2023-06-07T08:55:49Z |
| dc.date.available | 2024-02-04T01:29:33Z |
| dc.date.issued | 2022-02 |
| dc.description | © 2022 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. |
| dc.description.abstract | A non-invasive fetal electrocardiogram (FECG) is used to monitor the electrical pulse of the fetal heart. Decomposing the FECG signal from the maternal ECG (MECG) is a blind source separation problem, which is hard due to the low amplitude of the FECG, the overlap of R waves, and the potential exposure to noise from different sources. Traditional decomposition techniques, such as adaptive filters, require tuning, alignment, or pre-configuration, such as modeling the noise or desired signal to map the MECG to the FECG. The high correlation between maternal and fetal ECG fragments decreases the performance of convolution layers. Therefore, the masking region of interest based on the attention mechanism was performed to improve the signal generators' precision. The sine activation function was also used to retain more details when converting two signal domains. Three available datasets from the Physionet, including the A&D FECG, NI-FECG, and NI-FECG challenge, and one synthetic dataset using FECGSYN toolbox, were used to evaluate the performance. The proposed method could map an abdominal MECG to a scalp FECG with an average of 98% R-Square [CI 95%: 97%, 99%] as the goodness of fit on the A&D FECG dataset. Moreover, it achieved 99.7% F1-score [CI 95%: 97.8-99.9], 99.6% F1-score [CI 95%: 98.2%, 99.9%] and 99.3% F1-score [CI 95%: 95.3%, 99.9%] for fetal QRS detection on the A&D FECG, NI-FECG and NI-FECG challenge datasets, respectively. Also, the distortion was in the “very good” and “good” ranges. These results are comparable to the state-of-the-art results; thus, the proposed algorithm has the potential to be used for high-performance signal-to-signal conversion. |
| dc.description.peerreviewed | Peer Reviewed |
| dc.description.version | Postprint (author's final draft) |
| dc.format.extent | 12 p. |
| dc.identifier.citation | Mohebbian, M. [et al.]. Fetal ECG extraction from maternal ECG using attention-based cycleGAN. "IEEE journal of biomedical and health informatics", Febrer 2022, vol. 26, núm. 2, p. 515-526. |
| dc.identifier.doi | 10.1109/JBHI.2021.3111873 |
| dc.identifier.issn | 2168-2208 |
| dc.identifier.other | https://pubmed.ncbi.nlm.nih.gov/34516382/ |
| dc.identifier.uri | https://hdl.handle.net/2117/388306 |
| dc.language.iso | eng |
| dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| dc.relation.publisherversion | https://ieeexplore.ieee.org/document/9536378 |
| dc.rights.access | Open Access |
| dc.subject | Àrees temàtiques de la UPC::Enginyeria de la telecomunicació::Processament del senyal |
| dc.subject | Àrees temàtiques de la UPC::Enginyeria biomèdica::Electrònica biomèdica |
| dc.subject.lcsh | Fetal monitoring |
| dc.subject.lcsh | Electrocardiography |
| dc.subject.lemac | Monitoratge fetal |
| dc.subject.lemac | Electrocardiografia |
| dc.subject.other | Fetal ECG |
| dc.subject.other | CycleGAN |
| dc.subject.other | Blind source separation |
| dc.subject.other | Attention layer |
| dc.title | Fetal ECG extraction from maternal ECG using attention-based cycleGAN |
| dc.type | Article |
| dspace.entity.type | Publication |
| local.citation.author | Mohebbian, M.; Vedaei, S.; Wahid, K.; Dinh, A.; Marateb, H.; Tavakolian, K. |
| local.citation.endingPage | 526 |
| local.citation.number | 2 |
| local.citation.publicationName | IEEE journal of biomedical and health informatics |
| local.citation.startingPage | 515 |
| local.citation.volume | 26 |
| local.identifier.drac | 36593516 |
Fitxers
Paquet original
1 - 1 de 1
Carregant...
- Nom:
- Mohebbian et al., 2022.pdf
- Mida:
- 715.95 KB
- Format:
- Adobe Portable Document Format
- Descripció:
- Main article