Assessment of the economic and environmental impact of double glazed façade ventilation systems in Mediterranean climates

Carregant...
Miniatura
El pots comprar en digital a:
El pots comprar en paper a:

Projectes de recerca

Unitats organitzatives

Número de la revista

Títol de la revista

ISSN de la revista

Títol del volum

Col·laborador

Editor

Tribunal avaluador

Realitzat a/amb

Tipus de document

Article

Data publicació

Editor

Condicions d'accés

Accés obert

item.page.rightslicense

Creative Commons
Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Llevat que s'hi indiqui el contrari, els seus continguts estan subjectes a la llicència de Creative Commons: Reconeixement 3.0 Espanya

Assignatures relacionades

Assignatures relacionades

Publicacions relacionades

Datasets relacionats

Datasets relacionats

Projecte CCD

Abstract

Free convection is the most often used method in order to reduce solar load gains on a building with double glazed façades (DGFs). However, depending on the climate factors, the thermal performance of a DGF may not be satisfactory and extra energy costs are required to obtain suitable comfort conditions inside the building. Forced ventilation systems are a feasible alternative to improve the thermal performance of a DGF in Mediterranean climates where large solar gains are a permanent condition throughout the year. In this paper the feasibility of using diverse forced ventilation methods in DGF is evaluated. In addition, an economical comparison between different mechanical ventilation systems was performed in order to demonstrate the viability of DGF forced ventilation. Moreover, an environmental study was carried out to prove the positive energetic balance on cooling loads between free and forced convection in DGF for Mediterranean climates. For this investigation, a CFD model was used to simulate the thermal conditions in a DGF for the different ventilation systems. Results obtained for heat flux, temperature and reductions in solar load gains were analyzed and applied for the economic and environmental research.

Descripció

Persones/entitats

Document relacionat

Versió de

Citació

Valentin, D., Guardo, A., Egusquiza, E., Valero, M., Alavedra, P. Assessment of the economic and environmental impact of double glazed façade ventilation systems in Mediterranean climates. "Energies", 30 Setembre 2013, vol. 6, p. 5069-5087.

Ajut

Forma part

Dipòsit legal

ISBN

ISSN

1996-1073

Altres identificadors

Referències