Using machine learning and accelerometry data for differential diagnosis of Parkinson’s disease and essential tremor

Carregant...
Miniatura

Fitxers

manuscript (.pdf, 1.59 MB) (Accés restringit) Sol·licita una còpia a l'autor
El pots comprar en digital a:
El pots comprar en paper a:

Projectes de recerca

Unitats organitzatives

Número de la revista

Títol de la revista

ISSN de la revista

Títol del volum

Col·laborador

Editor

Tribunal avaluador

Realitzat a/amb

Tipus de document

Capítol de llibre

Data publicació

Editor

Springer

Condicions d'accés

Accés restringit per política de l'editorial

item.page.rightslicense

Creative Commons
Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Llevat que s'hi indiqui el contrari, els seus continguts estan subjectes a la llicència de Creative Commons: Reconeixement-NoComercial-SenseObraDerivada 3.0 Espanya

Assignatures relacionades

Assignatures relacionades

Publicacions relacionades

Datasets relacionats

Datasets relacionats

Projecte CCD

Abstract

Parkinson’s disease (PD) and Essential Tremor (ET) are the most common tremor syndromes in the world. Currently, a specific Single Photon Emission Computed Tomography (123I-FP-CIT SPECT) has proven to be an effective tool for the diagnosis of these diseases (97% sensitivity and 100% specificity). However, this test is invasive and expensive, and not all countries can have a SPECT system for an accurate differential diagnosis of PD patients. Clinical evaluation by a neurologist remains the gold standard for PD diagnosis, although the accuracy of this protocol depends on the experience and expertise of the physician. Wearable devices have been found to be a potential tool to help in differential diagnosis of PD and ET in early or complex cases. In this paper, we analyze the linear acceleration of the hand tremor recorded with a built-in accelerometer of a mobile phone, with a sampling frequency of 100 Hz. This hand tremor signal was thoroughly analyzed to extract different kinematic features in the frequency domain. These features were used to explore different Machine Learning methods to automatically classify and differentiate between healthy subjects and hand tremor patients (HETR Group) and, subsequently, patients with PD and ET (ETPD Group). Sensitivity of 90.0% and Specificity of 100.0% were obtained with classifiers of the HETR group. On the other hand, classifiers with Sensitivity ranges from 90.0% to 100.0% and Specificity from 80% to 100% were obtained for the ETPD group. These results indicate that the method proposed can be a potential tool to help the clinicians on differential diagnosis in complex or early hand tremor cases

Descripció

Persones/entitats

Document relacionat

Versió de

Citació

Loaiza , J. [et al.]. Using machine learning and accelerometry data for differential diagnosis of Parkinson’s disease and essential tremor. A: "Workshop on Engineering Applications". Berlín: Springer, 2019, p. 368-378.

Ajut

Forma part

Dipòsit legal

ISBN

978-3-030-31019-6

ISSN

Altres identificadors

Referències