Assessment and visualization of performance indicators of reinforced concrete beams by distributed optical fibre sensing

dc.contributor.authorGil Berrocal, Carlos
dc.contributor.authorFernández Pérez, Ignacio
dc.contributor.authorBado, Mattia Francesco
dc.contributor.authorCasas Rius, Joan Ramon
dc.contributor.authorRempling, Rasmus
dc.contributor.groupUniversitat Politècnica de Catalunya. EC - Enginyeria de la Construcció
dc.contributor.otherUniversitat Politècnica de Catalunya. Doctorat en Enginyeria de la Construcció
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental
dc.date.accessioned2021-04-08T07:43:06Z
dc.date.available2021-04-08T07:43:06Z
dc.date.issued2021-01
dc.description.abstractThe implementation of structural health monitoring systems in civil engineering structures already in the construction phase could contribute to safer and more resilient infrastructure. Due to their lightweight, small size and high resistance to the environment, distributed optical fibre sensors stand out as a very promising technology for damage detection and quantification in reinforced concrete structures. In this article, the suitability of embedding robust distributed optical fibre sensors featuring a protective sheath to accurately assess the performance indicators, in terms of vertical deflection and crack width, of three reinforced concrete beams subjected to four-point bending is investigated. The results revealed that a certain strain attenuation occurs in embedded robust distributed optical fibre sensors compared to commonly used thin polyimide-coated distributed optical fibre sensors bonded to steel reinforcement bars. However, the presence of the protective sheath prevented the appearance of strain reading anomalies which has been a frequently reported issue. Performance wise, the robust distributed optical fibre sensors were able to provide a good estimate of the beam deflections with errors of between 12.3% and 6.5%. Similarly, crack widths computed based on distributed optical fibre sensor strain measurements differed by as little as ±20¿µm with results from digital image correlation, provided individual cracks could be successfully detected in the strain profiles. Finally, a post-processing procedure is presented to generate intuitive contour plots that can help delivering critical information about the element’s structural condition in a clear and straightforward manner.
dc.description.peerreviewedPeer Reviewed
dc.description.sponsorshipThe author(s) disclosed receipt of the following financial support for the research, authorship and/or publication of this article: This research was performed as part of the project: ‘Sensor-driven Cloud-based Strategies for Infrastructure Management – SensIT’ funded by the Swedish Transport Administration (Trafikverket) under the grant TRV/BBT 2017-028.
dc.description.versionPostprint (published version)
dc.format.extent18 p.
dc.identifier.citationGil, C. [et al.]. Assessment and visualization of performance indicators of reinforced concrete beams by distributed optical fibre sensing. "Structural health monitoring: an international journal", 2021, vol. 20, núm. 6, p. 3309-3326.
dc.identifier.doi10.1177/1475921720984431
dc.identifier.issn1475-9217
dc.identifier.urihttps://hdl.handle.net/2117/343270
dc.language.isoeng
dc.relation.publisherversionhttps://journals.sagepub.com/doi/full/10.1177/1475921720984431
dc.rights.accessOpen Access
dc.rights.licensenameAttribution 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó
dc.subject.lcshOptical fiber detectors
dc.subject.lcshConcrete -- Cracking
dc.subject.lemacDetectors de fibra òptica
dc.subject.lemacFormigó -- Fissuració
dc.subject.otherReinforced concrete
dc.subject.otherDistributed optical fibre sensing
dc.subject.otherRayleigh backscattering
dc.subject.otherPerformance indicators
dc.subject.otherCrack monitoring
dc.titleAssessment and visualization of performance indicators of reinforced concrete beams by distributed optical fibre sensing
dc.typeArticle
dspace.entity.typePublication
local.citation.authorGil, C.; Fernández, I.; Bado, M.; Casas, J.; Rempling, R.
local.citation.endingPage3326
local.citation.number6
local.citation.publicationNameStructural health monitoring: an international journal
local.citation.startingPage3309
local.citation.volume20
local.identifier.drac30379178

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
30379178.pdf
Mida:
2.63 MB
Format:
Adobe Portable Document Format
Descripció: