Loss of blink regularity and its impact on ocular surface exposure

Carregant...
Miniatura
El pots comprar en digital a:
El pots comprar en paper a:

Projectes de recerca

Unitats organitzatives

Número de la revista

Títol de la revista

ISSN de la revista

Títol del volum

Col·laborador

Tribunal avaluador

Realitzat a/amb

Tipus de document

Article

Data publicació

Editor

Condicions d'accés

Accés obert

item.page.rightslicense

Creative Commons
Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Llevat que s'hi indiqui el contrari, els seus continguts estan subjectes a la llicència de Creative Commons: Reconeixement 4.0 Internacional

Assignatures relacionades

Assignatures relacionades

Publicacions relacionades

Datasets relacionats

Datasets relacionats

Projecte CCD

Abstract

Background: Changes in blink parameters have been found to influence ocular surface exposure, eliciting symptoms of dry eye and ocular signs. The aim of the study was to highlight the relevance of including blink regularity as a new parameter to fully characterize blinking; (2) Methods: A novel characterization of blink parameters is described, including spontaneous eyeblink rate (SEBR), percentage of incomplete blinks, and blink regularity. A pilot study was designed in which tear film break-up time (TFBUT), blink parameters, and the time percentage of ocular surface exposure were determined in eight subjects (52.0 ± 16.6 years, 4 females) in three experimental conditions (baseline, reading a hard-copy text, and reading from an electronic display). Blink parameters were monitored through asynchronous image analysis of one minute video segments; (3) Results: All blink parameters were influenced by experimental conditions. A trend was observed in which both reading tasks resulted in an increase in ocular surface exposure, mainly related to a combination of reduced SEBR, increased percentage of incomplete blinks, and loss of blink regularity; (4) Conclusions: A complete characterization of blink parameters is relevant to better understand ocular dryness related to surface exposure and to advice patients towards a reeducation of their blinking habits.

Descripció

Persones/entitats

Document relacionat

item.page.versionof

Citació

Cardona, G.; Argiles, M.; Pérez-Cabré, E. Loss of blink regularity and its impact on ocular surface exposure. "Diagnostics", 13 Juliol 2023, vol. 13, núm. 14, article 2362.

Ajut

Forma part

Dipòsit legal

ISBN

ISSN

2075-4418

Altres identificadors

Referències