An adaptive observer-based controller design for active damping of a DC network with a constant power load
Títol de la revista
ISSN de la revista
Títol del volum
Col·laborador
Editor
Tribunal avaluador
Realitzat a/amb
Tipus de document
Data publicació
Editor
Condicions d'accés
Llicència
Publicacions relacionades
Datasets relacionats
Projecte CCD
Abstract
This article explores a nonlinear, adaptive controller aimed at increasing the stability margin of a direct-current (dc), small-scale, electrical network containing an unknown constant power load (CPL). Due to its negative incremental impedance, this load reduces the effective damping of the network, which may lead to voltage oscillations and even to voltage collapse. To overcome this drawback, we consider the incorporation of a controlled dc-dc power converter in parallel with the CPL. The design of the control law for the converter is particularly challenging due to the existence of unmeasured states and unknown parameters. We propose a standard input-output linearization stage, to which a suitably tailored adaptive observer is added. The good performance of the controller is validated through experiments on a small-scale network.
Descripció
© 2021 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works