Experimental study on pressure fluctuation in header of nuclear power plant SEC system after long-term pump shutdown

Carregant...
Miniatura

Fitxers

20240415_ANE 110547.doc (5.49 MB) (Accés restringit) Sol·licita una còpia a l'autor
El pots comprar en digital a:
El pots comprar en paper a:

Projectes de recerca

Unitats organitzatives

Número de la revista

Títol de la revista

ISSN de la revista

Títol del volum

Col·laborador

Editor

Tribunal avaluador

Realitzat a/amb

Tipus de document

Article

Data publicació

Editor

Condicions d'accés

Accés restringit per política de l'editorial (embargat fins 2026-09-01)

item.page.rightslicense

Creative Commons
Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Llevat que s'hi indiqui el contrari, els seus continguts estan subjectes a la llicència de Creative Commons: Reconeixement-NoComercial-SenseObraDerivada 4.0 Internacional

Assignatures relacionades

Assignatures relacionades

Publicacions relacionades

Datasets relacionats

Datasets relacionats

Projecte CCD

Abstract

The Essential Service Water System (SEC) is a nuclear safety level system in nuclear power plants. It’s responsible for transporting the heat load collected by the equipment cooling water system (RRI) to the final heat sink – seawater. When the SEC system equipment is damaged, it can lead to ineffective heat transfer in RRI system, ultimately resulting in a major accident. Therefore, this article focuses on the SEC system of nuclear power plants and a technical solution combining model similarity experiments and theoretical analysis was adopted to restore the pressure fluctuation phenomenon that occurred after long-term pump shutdown of the SEC system, and the mechanism of pressure fluctuation phenomenon after long-term pump shutdown of the SEC system was analyzed. The results indicate that: the mechanism of pressure fluctuations in header of the nuclear power plant after long-term pump shutdown is the combined effect of an increase in the volume of the air chamber in the system and leakage in the check valve. In the design process of the unit, it is possible to consider reducing the high point position reasonably to improve the negative pressure situation of the SEC system, and it is recommended to replace the butterfly check valve with a two-stage slow closing check valve. This will provide certain experience and technical support for the further development of the SEC system.

Descripció

Persones/entitats

Document relacionat

Versió de

Citació

Chen, Y. [et al.]. Experimental study on pressure fluctuation in header of nuclear power plant SEC system after long-term pump shutdown. "Annals of nuclear energy", 1 Setembre 2024, vol. 204, núm. article 110547.

Ajut

Forma part

Dipòsit legal

ISBN

ISSN

0306-4549

Altres identificadors

Referències