Analyzing the role of emissivity in stranded conductors for overhead power lines

Carregant...
Miniatura
El pots comprar en digital a:
El pots comprar en paper a:

Projectes de recerca

Unitats organitzatives

Número de la revista

Títol de la revista

ISSN de la revista

Títol del volum

Col·laborador

Editor

Tribunal avaluador

Realitzat a/amb

Tipus de document

Article

Data publicació

Editor

Elsevier

Condicions d'accés

Accés obert

item.page.rightslicense

Creative Commons
Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Llevat que s'hi indiqui el contrari, els seus continguts estan subjectes a la llicència de Creative Commons: Reconeixement-NoComercial 4.0 Internacional

Assignatures relacionades

Assignatures relacionades

Publicacions relacionades

Datasets relacionats

Datasets relacionats

Projecte CCD

Abstract

Emissivity and absorptivity are important parameters in overhead power line conductors that depend on the conductor surface condition, so their values change as the conductors age. They have an important effect on their thermal behavior, so it is important to know their value when designing dynamic line rating (DLR) strategies. DLR methods are becoming increasingly important, especially in areas with congested power lines, as they allow the full capacity of the lines to be utilized by dynamically determining their maximum allowable currents without exceeding the safe temperature limits of the conductors, thus ensuring that they operate within safe limits. However, measuring emissivity and absorptivity is non-trivial and requires complex tests that cannot be performed in the field. Using simulations based on a realistic thermoelectric model and experimental tests performed on three types of transmission line conductors in a high-current laboratory, this paper shows the importance and effect of emissivity on conductor temperature. It also presents a method for measuring the emissivity value based on adjusting the emissivity and absorptivity values in the thermoelectric model to match the experimental values. The results presented show that aged conductors allow an increase in the maximum current carrying capacity compared to new conductors in the order of 5–14 %, depending on the conductor type considered and the operating conditions.

Descripció

Persones/entitats

Document relacionat

Versió de

Citació

Riba, J.; Liu, Y.; Moreno-Eguilaz, J.M. Analyzing the role of emissivity in stranded conductors for overhead power lines. "International journal of electrical power & energy systems", Agost 2024, vol. 159, núm. article 110027.

Ajut

Forma part

Dipòsit legal

ISBN

ISSN

0142-0615

Altres identificadors

Referències