A predictive model for fracture in human ribs based on in-vitro acoustic emission data

Carregant...
Miniatura
El pots comprar en digital a:
El pots comprar en paper a:

Projectes de recerca

Unitats organitzatives

Número de la revista

Títol de la revista

ISSN de la revista

Títol del volum

Col·laborador

Tribunal avaluador

Realitzat a/amb

Tipus de document

Article

Data publicació

Editor

Condicions d'accés

Accés obert

item.page.rightslicense

Creative Commons
Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Llevat que s'hi indiqui el contrari, els seus continguts estan subjectes a la llicència de Creative Commons: Reconeixement-NoComercial-SenseObraDerivada 3.0 Espanya

Assignatures relacionades

Assignatures relacionades

Publicacions relacionades

Datasets relacionats

Datasets relacionats

Projecte CCD

Abstract

Purpose

The aim of this paper is to propose a fracture model for human ribs based on acoustic emission (AE) data. The accumulation of microcracking until a macroscopic crack is produced can be monitored by AE. The macrocrack propagation causes the loss of the structural integrity of the rib. Methods

The AE technique was used in in vitro bending tests of human ribs. The AE data obtained were used to construct a quantitative model that allows an estimation of the failure stress from the signals detected. The model predicts the ultimate stress with an error of less than 3.5% (even at stresses 15% lower than failure stress), which makes it possible to safely anticipate the failure of the rib. Results

The percolation theory was used to model crack propagation. Moreover, a quantitative probability-based model for the expected number of AE signals has been constructed, incorporating some ideas of percolation theory. The model predicts that AE signals associated with micro-failures should exhibit a vertical asymptote when stress increases. The occurrence of this vertical asymptote was attested in our experimental observations. The total number of microfailures detected prior to the failure is urn:x-wiley:00942405:media:mp15082:mp15082-math-0001 and the ultimate stress is urn:x-wiley:00942405:media:mp15082:mp15082-math-0002 MPa. A significant correlation (p < 0.0001) between urn:x-wiley:00942405:media:mp15082:mp15082-math-0003 and the predicted value is found, using only the first N = 30 micro-failures (correlation improves for N higher). Conclusions

The measurements and the shape of the curves predicted by the model fit well. In addition, the model parameters seem to explain quantitatively and qualitatively the distribution of the AE signals as the material approaches the macroscopic fracture. Moreover, some of these parameters correlate with anthropometric variables, such as age or Body Mass Index. The proposed model could be used to predict the structural failure of ribs subjected to bending.