Sensor placement for combined sewer system monitoring in the Besòs river basin

dc.contributor.authorCosco, C.
dc.contributor.authorCugueró Escofet, Miquel Àngel
dc.contributor.authorTàsies, F.
dc.contributor.authorAguiló Martos, Pere
dc.contributor.authorGómez Valentín, Manuel
dc.contributor.groupUniversitat Politècnica de Catalunya. FLUMEN - Dinàmica Fluvial i Enginyeria Hidrològica
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental
dc.date.accessioned2018-11-06T16:36:22Z
dc.date.available2018-11-06T16:36:22Z
dc.date.issued2018-10
dc.description.abstractIn this paper, a sensor placement methodology for sewer systems monitoring in order to measure direct discharge to the river during intense rainfall events is presented. During these events, Combined Sewer Overflows (CSOs) may occur, causing serious problems of contamination of the corresponding receiving waters. The current national regulation compels sewer systems’ managers to monitor and quantify direct discharge to these receiving waters, in order to track these events. Hence, the selection of the appropriate sensor set in order to monitor the critical outlets of the network is of paramount importance to adequately monitor CSOs and minimize their effect by using the information gathered from these measurements. Here, a methodology considering relevant characteristics of each potential monitoring point —e.g. number of discharges, volume discharged or percentage of polluted mass— is defined to select the final sensor set. The presented methodology is applied to three different combined sewer systems in the Besòs river basin nearby Barcelona city area in Catalonia (Spain), i.e. Granollers, La Llagosta and Montornès systems.
dc.description.peerreviewedPeer Reviewed
dc.description.versionPostprint (published version)
dc.format.extent8 p.
dc.identifier.citationCosco, C., Cugueró-Escofet, M.A., Tàsies, F., Aguiló-Martos, P., Gomez, M. Sensor placement for combined sewer system monitoring in the Besòs river basin. "IFAC-PapersOnLine", Octubre 2018, vol. 51, núm. 24, p. 949-956.
dc.identifier.doi10.1016/j.ifacol.2018.09.689
dc.identifier.issn2405-8963
dc.identifier.urihttps://hdl.handle.net/2117/123661
dc.language.isoeng
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S2405896318324078
dc.rights.accessOpen Access
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Enginyeria hidràulica, marítima i sanitària::Enginyeria sanitària
dc.subject.lcshSewerage--Spain--Barcelona
dc.subject.lemacClavegueram -- Catalunya -- Barcelona
dc.subject.otherReal-time monitoring sensor placement direct discharge water quality outlet combined sewer overflow
dc.titleSensor placement for combined sewer system monitoring in the Besòs river basin
dc.typeArticle
dspace.entity.typePublication
local.citation.authorCosco, C.; Cugueró-Escofet, M.A.; Tàsies, F.; Aguiló-Martos, P.; Gomez, M.
local.citation.endingPage956
local.citation.number24
local.citation.publicationNameIFAC-PapersOnLine
local.citation.startingPage949
local.citation.volume51
local.identifier.drac23501406

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
23501406.pdf
Mida:
1.03 MB
Format:
Adobe Portable Document Format