Diagnosis of the unstable behaviour of a Kaplan turbine before synchronizing to the grid

dc.contributor.authorMoraga González, Greco Alonso
dc.contributor.authorHijón Montero, Cristina
dc.contributor.authorGirardelo, Jeferson
dc.contributor.authorValentín Ruiz, David
dc.contributor.authorEgusquiza Montagut, Mònica
dc.contributor.authorEgusquiza Estévez, Eduard
dc.contributor.authorPresas Batlló, Alexandre
dc.contributor.groupUniversitat Politècnica de Catalunya. CDIF - Centre de Diagnòstic Industrial i Fluidodinàmica
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Mecànica de Fluids
dc.date.accessioned2025-04-09T08:32:58Z
dc.date.available2025-04-09T08:32:58Z
dc.date.issued2024-11-01
dc.description.abstractThis work reports on a new Kaplan turbine that experienced an unstable behaviour during its start up. The unit experienced strong sound and vibration in that phase. To identify the origin of this unstable behaviour, a set of sensors were installed within the turbine. Subsequently, tests were performed to determine the response of the different sensors during the acceleration of the machine to the speed no load stage. Following a thorough analysis of the results, the problem was identified as the air admission openings of the head cover and their distribution. To address this issue, a reconfiguration of these openings was implemented and their performance was evaluated. Following this rearrangement, the vibrations in the head cover were significantly reduced and the unit was successfully commissioned.
dc.description.peerreviewedPeer Reviewed
dc.description.sponsorshipGreco Moraga received funding from the National Agency for Research and Development (ANID) / Scholarship Program / DOCTORADO BECAS CHILE/2020 – 72210054 for his PhD scholarship. Alexandre Presas and David Valentin want to acknowledge the Serra Hunter Program of Generalitat de Catalunya.
dc.description.versionPostprint (published version)
dc.format.extent9 p.
dc.identifier.citationMoraga, G. [et al.]. Diagnosis of the unstable behaviour of a Kaplan turbine before synchronizing to the grid. "IOP conference series: earth and environment", 1 Novembre 2024, vol. 1411, núm. article 012022.
dc.identifier.doi10.1088/1755-1315/1411/1/012022
dc.identifier.issn1755-1307
dc.identifier.urihttps://hdl.handle.net/2117/427779
dc.language.isoeng
dc.publisherInstitute of Physics (IOP)
dc.relation.publisherversionhttps://iopscience.iop.org/article/10.1088/1755-1315/1411/1/012022
dc.rights.accessOpen Access
dc.rights.licensenameAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectÀrees temàtiques de la UPC::Enginyeria mecànica::Mecànica de fluids
dc.titleDiagnosis of the unstable behaviour of a Kaplan turbine before synchronizing to the grid
dc.typeArticle
dspace.entity.typePublication
local.citation.authorMoraga, G.; Hijón, C.; Girardelo, J.; Valentin, D.; Egusquiza, M.; Egusquiza, E.; Presas, A.
local.citation.numberarticle 012022
local.citation.publicationNameIOP conference series: earth and environment
local.citation.volume1411