A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables: a simulation case

Carregant...
Miniatura
El pots comprar en digital a:
El pots comprar en paper a:

Projectes de recerca

Unitats organitzatives

Número de la revista

Títol de la revista

ISSN de la revista

Títol del volum

Col·laborador

Editor

Tribunal avaluador

Realitzat a/amb

Tipus de document

Article

Data publicació

Editor

ELSEVIER

Condicions d'accés

Accés obert

item.page.rightslicense

Creative Commons
Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Llevat que s'hi indiqui el contrari, els seus continguts estan subjectes a la llicència de Creative Commons: Reconeixement-NoComercial-SenseObraDerivada 3.0 Espanya

Assignatures relacionades

Assignatures relacionades

Publicacions relacionades

Datasets relacionats

Datasets relacionats

Projecte CCD

Abstract

Eye movement artifacts represent a critical issue for quantitative electroencephalography (EEG) analysis and a number of mathematical approaches have been proposed to reduce their contribution in EEG recordings. The aim of this paper was to objectively and quantitatively evaluate the performance of ocular filtering methods with respect to spectral target variables widely used in clinical and functional EEG studies. In particular the following methods were applied: regression analysis and some blind source separation (BSS) techniques based on second-order statistics (PCA, AMUSE and SOBI) and on higher-order statistics (JADE, INFOMAX and FASTICA). Considering blind source decomposition methods, a completely automatic procedure of BSS based on logical rules related to spectral and topographical information was proposed in order to identify the components related to ocular interference. The automatic procedure was applied in different montages of simulated EEG and electrooculography (EOG) recordings: a full montage with 19 EEG and 2 EOG channels, a reduced one with only 6 EEG leads and a third one where EOG channels were not available. Time and frequency results in all of them indicated that AMUSE and SOBI algorithms preserved and recovered more brain activity than the other methods mainly at anterior regions. In the case of full montage: (i) errors were lower than 5% for all spectral variables at anterior sites; and (ii) the highest improvement in the signal-to-artifact (SAR) ratio was obtained up to 40 dB at these anterior sites. Finally, we concluded that second-order BSS-based algorithms (AMUSE and SOBI)

Descripció

Persones/entitats

Document relacionat

Versió de

Citació

Romero, S.; Mañanas, M.; Barbanoj, M. A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables: a simulation case. "Computers in biology and medicine", Març 2008, vol. 38, núm. 3, p. 348-360.

Ajut

Forma part

Dipòsit legal

ISBN

ISSN

0010-4825

Altres identificadors

Referències