Browsing by Author "Marco, Santiago"
Now showing items 1-17 of 17
-
A method to build unique calibration models for batches of chemical sensor arrays
Fonollosa Magrinyà, Jordi; Rodriguez-Perez, Raquel; Solórzano, Ana; Padilla, Marta; Graunke, Thorsten; Marco, Santiago (2016)
Conference report
Open Access -
Application of an array of metal-oxide semiconductor gas sensors in an assistant personal robot for early gas leak detection
Palacín Roca, Jordi; Martínez Ortín, David; Clotet Bellmunt, Eduard; Pallejà Cabré, Tomàs; Burgués Calderón, Javier; Fonollosa Magrinyà, Jordi; Pardo, Antonio; Marco, Santiago (Multidisciplinary Digital Publishing Institute (MDPI), 2019-04-26)
Article
Open Access -
Calibration transfer and drift counteraction in chemical sensor arrays using direct standardization
Fonollosa Magrinyà, Jordi; Fernandez, Luis; Gutiérrez-Gálvez, Agustín; Huerta, Ramon; Marco, Santiago (2016-05-18)
Article
Open AccessInherent variability of chemical sensors makes it necessary to calibrate chemical detection systems individually. This shortcoming has traditionally limited usability of systems based on metal oxide gas sensor arrays and ... -
Chemical sensor systems and associated algorithms for fire detection: A review
Fonollosa Magrinyà, Jordi; Solórzano, Ana; Marco, Santiago (Multidisciplinary Digital Publishing Institute (MDPI), 2018)
Article
Open AccessIndoor fire detection using gas chemical sensing has been a subject of investigation since the early nineties. This approach leverages the fact that, for certain types of fire, chemical volatiles ... -
Design and fabrication of silicon-based mid infrared multi-lenses for gas sensing applications
Fonollosa Magrinyà, Jordi; Rubio, Rafael; Hartwig, S; Marco, Santiago; Santander, Joaquim; Fonseca, Luis; Wöllenstein, Jürgen; Moreno-Sereno, Mauricio (2008)
Article
Restricted access - publisher's policy -
Discontinuously operated MOX sensors for low power applications
Burgués, Javier; Fonollosa Magrinyà, Jordi; Marco, Santiago (2017)
Conference report
Open AccessMetal oxide semiconductor sensors are limited by their low selectivity, high power consumption and temporal drift. This paper proposes a novel discontinuous temperature modulation operation mode characterized by ondemand ... -
Ethylene optical spectrometer for apple ripening monitoring in controlled atmosphere store-houses
Fonollosa Magrinyà, Jordi; Halford, Bern; Fonseca, Luis; Santander, Joaquim; Udina, Sergi; Moreno-Sereno, Mauricio; Hildenbrand, Jürgen; Wöllenstein, Jürgen; Marco, Santiago (2009)
Article
Restricted access - publisher's policy -
Exploration of the metrological performance of a gas detector based on an array of unspecific infrared filters
Rubio, Rafael; Santander, Joaquim; Fonollosa Magrinyà, Jordi; Fonseca, Luis; Gràcia, I; Cané Ballart, Carles; Moreno-Sereno, Mauricio; Marco, Santiago (2006)
Article
Restricted access - publisher's policy -
Fire detection using a gas sensor array with sensor fusion algorithms
Solórzano, Ana; Fonollosa Magrinyà, Jordi; Fernández Romero, Lluís; Eichmann, Jens; Marco, Santiago (2017)
Conference lecture
Open AccessConventional fire alarms are based on smoke detection. Nevertheless, in some fire scenarios volatiles are released before smoke. Fire detectors based only on chemical sensors have already been proposed as they may provide ... -
Gas sensor array for reliable fire detection
Fonollosa Magrinyà, Jordi; Solórzano, Ana; Jimenez-Soto, Juan; Oller-Moreno, Sergi; Marco, Santiago (2016)
Conference report
Open Access -
Improving calibration of chemical gas sensors for fire detection using small scale setups
Solórzano, Ana; Fonollosa Magrinyà, Jordi; Marco, Santiago (Multidisciplinary Digital Publishing Institute (MDPI), 2017)
Conference report
Open AccessChemical sensing may be better suited than conventional smoke-based detectors for the detection of certain type of fires, in particular in fires where smoke appears after gas emissions. However, chemical-based systems also ... -
Limits to the integration of filters and lenses on thermoelectric IR detectors by flip-chip techniques
Fonollosa Magrinyà, Jordi; Carmona, Manuel; Santander, Joaquim; Fonseca, Luis; Moreno-Sereno, Mauricio; Marco, Santiago (2009)
Article
Restricted access - publisher's policy -
Multi-unit calibration rejects inherent device variability of chemical sensor arrays
Solórzano, Ana; Rodriguez-Perez, Raquel; Padilla, Marta; Graunke, Thorsten; Fernández Romero, Lluís; Marco, Santiago; Fonollosa Magrinyà, Jordi (2018)
Article
Open Access -
Odour mapping under strong backgrounds with a metal oxide sensor array
Ziyatdinov, Andrey; Blanco Calvo, Jose Maria; Bermudez Badia, Sergi; Lechon, Miguel; Marco, Santiago; Verschure, Paul; Perera Lluna, Alexandre (American Institute of Physics (AIP), 2011)
Conference report
Open AccessThis text describes the data from an initial set of navigation experiments in the scope of the Bio-ICT European project NEUROCHEM (...) This poster shows that a preprocessing based on Independent Component Analysis is able ... -
Quality coding by neural populations in the early olfactory pathway: analysis using information theory and lessons for artificial olfactory systems
Fonollosa Magrinyà, Jordi; Gutiérrez-Gálvez, Agustín; Marco, Santiago (2012)
Article
Open Access -
Sequence information gain based motif analysis
Maynou Fernández, Joan; Pairó, Erola; Marco, Santiago; Perera Lluna, Alexandre (2015-11-09)
Article
Open AccessBackground: The detection of regulatory regions in candidate sequences is essential for the understanding of the regulation of a particular gene and the mechanisms involved. This paper proposes a novel methodology based ... -
Temperature optimization of metal-oxide sensor arrays using mutual information
Fonollosa Magrinyà, Jordi; Fernandez, Luis; Huerta, Ramon; Gutiérrez-Gálvez, Agustín; Marco, Santiago (2013)
Article
Restricted access - publisher's policy