• 100 GHz retina for THz tomographic imaging 

      Alonso, Maria; Guerra, C.; Nova, Enrique; Abril, Jordi; Romeu Robert, Jordi; Llombart, Nuria; Jofre Roca, Lluís (2011)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      In a tomographic imaging system, the key is to collect a sufficient number of scattered field points to recover the currents in the inverse scattering problem. This can be accomplished by using a real array of multiplexed ...
    • Real time 100 GHz MST imaging retina 

      Alonso del Pino, María; Garg, V.; García Guerra, Carlos Enrique; Romeu Robert, Jordi; Llombart, Nuria; Jofre Roca, Lluís (Institute of Electrical and Electronics Engineers (IEEE), 2012)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      A real time tomographic imaging system at 100 GHz based on a retina and Modulated Scattered Technique (MST) is presented in this paper. It consists in applying a low frequency modulation to each probe of an array of antennas ...
    • Retina design for 100GHz MST imaging system 

      Alonso, Maria; Garg, V.; Nova, Enrique; Abril, Jordi; Romeu Robert, Jordi; Llombart, Nuria; Jofre Roca, Lluís (Institute of Electrical and Electronics Engineers (IEEE), 2012)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      A near field imaging system for THz tomographic imaging based on a MST retina (an array of real antennas) has been designed. The main adva ntage of this implementation is the absence of microwave transmission line ...
    • Silicon micro-lens antennas for THz integrated arrays 

      Alonso del Pino, María; Llombart, Nuria; Lee, Clement; Jung, C.; Chattopadhyay, G.; Jofre Roca, Lluís; Mehdi, Imran (IEEE, 2011)
      Article
      Accés restringit per política de l'editorial
      In this paper, we describe the characterization of silicon micro-lenses fabricated by two different techniques, one using laser micromachining and the other developed using photolithographical techniques. The micro-lens ...
    • Tomographic imaging retina at 100 GHz 

      Alonso, Maria; Garg, V; Romeu Robert, Jordi; Llombart, Nuria; Jofre Roca, Lluís (IEEEXPLORE, 2012)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      This paper presents a tomographic system at 100 GHz for imaging based on MST technique. At 100 GHz, a good compromise is obtained between penetration and reso- lution for biomedical and non-destructive testing ...