Losses and CMV evaluation in transformerless grid-connected PV topologies
Vázquez Guzmán, Gerardo; Kerekes, Tamas; Rolán Blanco, Alejandro; Aguilar Gaván, Daniel; Luna Alloza, Álvaro; Acevedo, Gustavo (2009)
Conference lecture
Open AccessControlling the thermal losses in the semiconductors ~s well. as the Co~mon Mode Voltage (CMV), are important Issues In the design of power electronics converters for photovoltaic applications. At present time there are ... -
Modeling and control of a three-phase grid-connected inverter under fault conditions
Rolán Blanco, Alejandro; Giménez, Pablo; Yague, Sauro J.; Bogarra Rodríguez, Santiago (Institute of Electrical and Electronics Engineers (IEEE), 2018)
Conference report
Restricted access - publisher's policyThe aim of this paper is to study the behavior of a three-phase inverter with an RL filter powered by a renewable energy source and connected to a grid under fault conditions. The novelty of the work lies in proposing a ... -
Modeling and simulation of synchronous machine and its behaviour against voltage sags
Aguilar Gaván, Daniel; Luna Alloza, Álvaro; Rolán Blanco, Alejandro; Vázquez Guzmán, Gerardo; Acevedo, Gustavo (2009)
Conference lecture
Open AccessThis paper studies the effects of voltage sags (dips), both symmetrical and unsymmetrical, on the three-phase Synchronous Machine (SM). The vast majority of the electrical power generation systems in the world is consist ... -
Modeling of a variable speed wind turbine with a permanent magnet synchronous generator
Rolán Blanco, Alejandro; Luna Alloza, Álvaro; Vázquez Guzmán, Gerardo; Aguilar Gaván, Daniel; Acevedo, Gustavo (2009)
Conference lecture
Open AccessThe aim of this work is to analyze a typical configuration of a Wind Turbine Generator System (WTGS) equipped with a Variable Speed Generator. Nowadays, doublyfed induction generators are being widely used on WTGS, although ... -
New smart sensor for voltage unbalance measurements in electrical power systems
Bogarra Rodríguez, Santiago; Saura Perisé, Jaime; Rolán Blanco, Alejandro (Multidisciplinary Digital Publishing Institute (MDPI), 2022-10-27)
Article
Open AccessThis paper deals with voltage unbalances and how they can be quantified according to the standards. Firstly, a comparison between the different unbalance voltage factors is conducted in order to remark on their divergences. ... -
On fixed-speed WT generator modeling for rotor speed stability studies
Pedra Durán, Joaquim; Córcoles López, Felipe; Monjo Mur, Lluís; Bogarra Rodríguez, Santiago; Rolán Blanco, Alejandro (2012-02)
Article
Restricted access - publisher's policyThis paper analyzes fixed-speed induction generator modeling oriented to rotor speed stability studies. The single- and double-cage models are compared. The effects of symmetrical voltage sags on generator behavior are ... -
Photovoltaic inverters with fault ride-through capability
Azevedo, Gustavo M.S.; Vázquez, Gerardo; Luna Alloza, Álvaro; Aguilar Galván, Daniel; Rolán Blanco, Alejandro (ISIE, 2009)
Conference lecture
Open AccessThis paper presents a new control strategy that allow the photovoltaic system operate under grid faults without overpass the rated current and assuring sinusoidal currents. In the classic control strategies used in ... -
Reduced-order models of squirrel-cage induction generators for fixed-speed wind turbines under unbalanced grid conditions
Rolán Blanco, Alejandro; Córcoles López, Felipe; Bogarra Rodríguez, Santiago; Monjo Mur, Lluís; Pedra Durán, Joaquim (2016-06)
Article
Open AccessThis paper develops a study of reduced-order models for squirrel-cage induction generators used in the fixed-speed wind turbines. The squirrel-cage of these generators must be modeled with a double-cage for accuracy purposes. ... -
Simulation of wound rotor synchronous machine under voltage sags
Aguilar Galván, Daniel; Vázquez Guzmán, Gerardo; Rolán Blanco, Alejandro; Rocabert Delgado, Joan; Córcoles López, Felipe; Rodríguez Cortés, Pedro (IEEE Press. Institute of Electrical and Electronics Engineers, 2010)
Conference lecture
Open AccessThis paper presents a study of the Wound Rotor Synchronous Machine (SM) stability under voltage sags (dips). Machine behavior has been analyzed by considering different magnitudes (or depths) and duration of the sag. ... -
Small synchronous machine protection during voltage sags caused by MV grid faults
Bogarra Rodríguez, Santiago; Rubion, X.; Rolán Blanco, Alejandro; Córcoles López, Felipe; Pedra Durán, Joaquim; Iglesias, J. (2018-03-01)
Article
Open AccessThis paper analyses the impact of symmetrical and unsymmetrical voltage sags caused by distribution and transmission faults on the dynamic behaviour of small salient-pole synchronous machines connected to the MV grid, and ... -
Symmetrical and unsymmetrical voltage sag effects on the three-phase synchronous machine stability
Aguilar Galván, Daniel; Rolán Blanco, Alejandro; Vázquez, Gerardo; Córcoles López, Felipe; Rodríguez Cortés, Pedro (2009)
Conference lecture
Open AccessThis paper focuses on the effects of voltage sags, both symmetrical and unsymmetrical, on the three-phase Synchronous Machine (SM). Voltage sags on SM cause speed variations, current and torque peaks and hence may cause ... -
TEORIA DE CIRCUITS (1a avaluació)
Rolán Blanco, Alejandro (Universitat Politècnica de Catalunya, 2009-10-29)
Exam
Restricted access to the UPC academic community -
TEORIA DE CIRCUITS (Prova final)
Rolán Blanco, Alejandro (Universitat Politècnica de Catalunya, 2010-01-13)
Exam
Restricted access to the UPC academic community -
Testing of three-phase equipment under voltage sags
Rolán Blanco, Alejandro; Córcoles López, Felipe; Pedra Durán, Joaquim; Monjo Mur, Lluís; Bogarra Rodríguez, Santiago (2015-04-09)
Article
Open AccessThis paper provides insight into the testing of three-phase equipment exposed to voltage sags caused by faults. The voltage sag recovers at the fault-current zeros, leading to a ‘discrete’ voltage recovery, that is, the ... -
Voltage recovery influence on three-phase grid-connected inverters under voltage sags
Rolán Blanco, Alejandro; Giménez, Pablo; Yague, Sauro J.; Bogarra Rodríguez, Santiago; Saura Perisé, Jaime; Bakkar, Mostafa (2019-02-12)
Article
Open AccessFaults in power systems cause voltage sags, which, in turn, provoke large current peaks in grid-connected equipment. Then, a complete knowledge of the inverter behaviour is needed to meet fault ride-through capability. The ... -
Voltage sag influence on controlled three-phase grid-connected inverters according to the Spanish grid code
Bakkar, Mostafa; Bogarra Rodríguez, Santiago; Rolán Blanco, Alejandro; Córcoles López, Felipe; Saura Perisé, Jaime (2020-02-03)
Article
Open AccessTo ensure the safe operation of the grid, there are some requirements to be taken into consideration to connect power converters. During abnormal conditions – e.g. during voltage sags –, the control of the converters is a ...