  • Behaviour of the doubly fed induction generator exposed to unsymmetrical voltage sags 

    Rolán Blanco, Alejandro; Córcoles López, Felipe; Pedra Durán, Joaquim (2012-09)
    Article
    Restricted access - publisher's policy
    This study analyses the dynamic behaviour of the doubly fed induction generator exposed to unsymmetrical voltage sags, providing insights into wind turbine fault ride-through capability. The sags are assumed to be caused ...
  • Comparison of simplified models for voltage-source-inverter-fed adjustable-speed drive during voltage sags when the during-event continue mode of operation is active 

    Bogarra Rodríguez, Santiago; Monjo Mur, Lluís; Saura Perisé, Jaime; Córcoles López, Felipe; Pedra Durán, Joaquim (2014-11-13)
    Article
    Restricted access - publisher's policy
    Three simplified models for adjustable-speed drives are compared with measurements on an actual drive where the inverter control strategy remains unaltered during the event (also known as continue mode of operation) to ...
  • Control of DFIG-WT under unbalanced grid voltage conditions 

    Luna Alloza, Álvaro; Rodríguez Cortés, Pedro; Lima, Kleber; Córcoles López, Felipe; Watanabe, Edson H.; Teodorescu, R. (2009)
    Conference lecture
    Open Access
    The voltage oriented control in the synchronous reference frame (VOC-SRF) have been extensively used for controlling wind turbines based on doubly fed induction generators (DFIG-WTs) through the rotor side converter of ...
  • Control of power converters in distributed generation applications under grid fault conditions 

    Rodríguez Cortés, Pedro; Luna Alloza, Álvaro; Muñoz Aguilar, Raúl Santiago; Córcoles López, Felipe; Teodorescu, Remus; Blaabjerg, Frede (IEEE, 2011)
    Conference report
    Restricted access - publisher's policy
    The operation of distributed power generation systems under grid fault conditions is a key issue for the massive integration of renewable energy systems. Several studies have been conducted to improve the response of ...
  • Control proposals for the operation of power converters in wind power systems 

    Luna Alloza, Álvaro; Aguilar, Daniel; Muñoz Aguilar, Raúl Santiago; Córcoles López, Felipe; Rodríguez Cortés, Pedro (IEEE, 2011)
    Conference report
    Open Access
    The wind turbines based on Doubly Fed Induction Generators (DFIG) represent almost the 60% of the installed windpower worldwide. Nowadays most of the existing algorithms, used for regulating the production of active and ...
  • Detailed study of DFIG-based wind turbines to overcome the most severe grid faults 

    Rolán Blanco, Alejandro; Pedra Durán, Joaquim; Córcoles López, Felipe (2014-11-01)
    Article
    Restricted access - publisher's policy
    This paper studies the effects of voltage sags caused by faults on doubly-fed induction generators to overcome grid faults. A wide range of sag duration and depth values is considered. It is observed that sag duration ...
  • Discrete fault-clearing instant influence on the simulation of voltage-source-inverter-fed adjustable-speed drives subjected to voltage sags 

    Córcoles López, Felipe; Bogarra Rodríguez, Santiago; Pedra Durán, Joaquim; Luna Alloza, Álvaro (2011-05)
    Article
    Restricted access - publisher's policy
    This study analyses the influence of modelling sags with discrete fault-clearing instants on the behaviour of adjustablespeed drives (ASDs) subjected to sags caused by faults. The effects are compared with those of sags ...
  • Doubly fed induction generator subject to symmetrical voltage sags 

    Rolán Blanco, Alejandro; Córcoles López, Felipe; Pedra Durán, Joaquim (2011-12)
    Article
    Restricted access - publisher's policy
    The aim of this paper is to analyze the dynamic behavior of the doubly fed induction generator (DFIG) subject to symmetrical voltage sags caused by three-phase faults. A simple control algorithm is considered and assumed ...
  • Grid synchronization for advanced power processing and FACTS in wind power systems 

    Luna Alloza, Álvaro; Rocabert Delgado, Joan; Vázquez Guzmán, Gerardo; Rodríguez Cortés, Pedro; Teodorescu, Remus; Córcoles López, Felipe (2010)
    Conference report
    Open Access
    The high penetration of wind power systems in the electrical network has introduced new issues in the stability and transient operation of the grid. By means of providing advanced functionalities to the existing power ...
  • On fixed-speed WT generator modeling for rotor speed stability studies 

    Pedra Durán, Joaquim; Córcoles López, Felipe; Monjo Mur, Lluís; Bogarra Rodríguez, Santiago; Rolán Blanco, Alejandro (2012-01-20)
    Article
    Restricted access - publisher's policy
    This paper analyzes fixed-speed induction generator modeling oriented to rotor speed stability studies. The single- and double-cage models are compared. The effects of symmetrical voltage sags on generator behavior are ...
  • Parameter estimation of squirrel-cage motors with parasitic torques in the torque–slip curve 

    Monjo Mur, Lluís; Córcoles López, Felipe; Pedra Durán, Joaquim (2015-04-16)
    Article
    Open Access
    This paper studies parasitic torques in steady-state torque–slip curves of squirrel-cage induction motors. The curves of nine motors (small, medium and large size units), three of which were measured in the range s = 2 ...
  • Parameter estimation of wound-rotor induction motors from transient measurements 

    Kojooyan, Hengameh; Monjo Mur, Lluís; Córcoles López, Felipe; Pedra Durán, Joaquim (2014-06)
    Article
    Restricted access - publisher's policy
    A new method for determination of the steady-state equivalent circuit parameters of wound-rotor induction motors using experimental data from starting transient measurements is presented. The algorithm data are the stator ...
  • Power control strategies during voltage sags according to Spanish grid code 

    Bogarra Rodríguez, Santiago; Córcoles López, Felipe; Saura Perisé, Jaime; Moreno Eguilaz, Juan Manuel; Bakkar, Mostafa (2018)
    Conference report
    Open Access
    In order to connect any power converters into the grid there are some grid requirements to insure the safe operation of the grid. So, the control of the converters especially during abnormal ...
  • Power quality aspects of smart grids 

    Bollen, Math H.J.; Zhong, Jin; Zavoda, Francisc; Meyer, Jan; McEachern, Alex; Córcoles López, Felipe (2010)
    Conference report
    Open Access
    This paper gives an overview of the smart grids developments, seen from a power-quality viewpoint; describes the main relations between smart grids and power quality, and goes into some detail for some of the aspects. ...
  • Saturation effects on torque- and current–slip curves of squirrel-cage induction motors 

    Monjo Mur, Lluís; Córcoles López, Felipe; Pedra Durán, Joaquim (2012-12-24)
    Article
    Restricted access - publisher's policy
    This paper measures and analyzes the saturation effects on torque- and current–slip curves of three squirrel-cage induction motors.Motor saturation is illustrated by three sets of measurements: I) torque and current for ...
  • Simulation of wound rotor synchronous machine under voltage sags 

    Aguilar Galván, Daniel; Vázquez Guzmán, Gerardo; Rolán Blanco, Alejandro; Rocabert Delgado, Joan; Córcoles López, Felipe; Rodríguez Cortés, Pedro (IEEE Press. Institute of Electrical and Electronics Engineers, 2010)
    Conference lecture
    Open Access
    This paper presents a study of the Wound Rotor Synchronous Machine (SM) stability under voltage sags (dips). Machine behavior has been analyzed by considering different magnitudes (or depths) and duration of the sag. ...
  • Small synchronous machine protection during voltage sags caused by MV grid faults 

    Bogarra Rodríguez, Santiago; Rubion, X.; Rolan, Alejandro; Córcoles López, Felipe; Pedra Durán, Joaquim; Iglesias, J. (2018-03-01)
    Article
    Restricted access - publisher's policy
    This paper analyses the impact of symmetrical and unsymmetrical voltage sags caused by distribution and transmission faults on the dynamic behaviour of small salient-pole synchronous machines connected to the MV grid, and ...
  • Squirrel-cage induction motor parameter estimation using a variable frequency test 

    Monjo Mur, Lluís; Kojooyan, Hengameh; Córcoles López, Felipe; Pedra Durán, Joaquim (2015-06-01)
    Article
    Open Access
    This paper presents amethod for squirrel-cage induction motor parameter estimation using a phase-to-phase standstill variable frequency test. The measured resistance and reactance at different frequencies are the data of ...
  • Testing of three-phase equipment under voltage sags 

    Rolán Blanco, Alejandro; Córcoles López, Felipe; Pedra Durán, Joaquim; Monjo Mur, Lluís; Bogarra Rodríguez, Santiago (2015-04-09)
    Article
    Open Access
    This paper provides insight into the testing of three-phase equipment exposed to voltage sags caused by faults. The voltage sag recovers at the fault-current zeros, leading to a ‘discrete’ voltage recovery, that is, the ...
  • Using the instantaneous power of a free acceleration test for squirrel-cage motor parameters estimation 

    Kojooyan, Hengameh; Monjo Mur, Lluís; Córcoles López, Felipe; Pedra Durán, Joaquim (2015-09-01)
    Article
    Open Access
    A new parameters determination method for squirrel-cage induction motors is presented. As a main contribution, the method uses the instantaneous electrical power and the mechanical speed measured in a free acceleration ...