Ara es mostren els items 1-13 de 13

    • Analysis of the misfit of dental implant-supported prostheses made with three manufacturing processes 

      Fernández Yagüe, Marc-Antoni; Delgado Garoña, Luis María; Molmeneu Trias, Meritxell; García, David; Rodríguez Rius, Daniel (2014-02-01)
      Article
      Accés restringit per política de l'editorial
      The microgap between implant components has been associated with complications such as screw loosening or adverse biologic responses.
    • Antibacterial properties of triethoxysilylpropyl succinic anhydride silane (TESPSA) on titanium dental implants 

      Buxadera Palomero, Judit; Godoy Gallardo, María; Molmeneu Trias, Meritxell; Punset Fuste, Miquel; Gil Mur, Francisco Javier (Multidisciplinary Digital Publishing Institute (MDPI), 2020-04-01)
      Article
      Accés obert
      Realitzat a/amb:   Universitat Internacional de Catalunya
      Infections related to dental implants are a common complication that can ultimately lead to implant failure, and thereby carries significant health and economic costs. In order to ward off these infections, this paper ...
    • Bioactive macroporous titanium implants highly interconnected 

      Caparrós, Cristina; Ortiz Hernández, Mónica; Molmeneu Trias, Meritxell; Punset Fuste, Miquel; Calero Martínez, José Antonio; Aparicio Badenas, Conrado José; Fernández Fairén, Mariano; Pérez Antoñanzas, Román; Gil Mur, Francisco Javier (Springer, 2016-10-01)
      Article
      Accés restringit per política de l'editorial
      Realitzat a/amb:   AMES / University of Minnesota School of Dentistry / Universitat Internacional de Catalunya
      Intervertebral implants should be designed with low load requirements, high friction coefficient and low elastic modulus in order to avoid the stress shielding effect on bone. Furthermore, the presence of a highly ...
    • Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth 

      Martin Gili, D.; Molmeneu Trias, Meritxell; Fernández Yagüe, Marc-Antoni; Punset Fuste, Miquel; Giner, Li; Armengou, Jaume; Gil Mur, Francisco Javier (2015-07-01)
      Article
      Accés obert
      This study shows the potential risk of microfiltration between two different types of implant-abutment connections screwed at 45 Ncm: external and internal. For the first time the use of a mechanical artificial mouth is ...
    • Differences between the fittings of dental prostheses produced by CAD-CAM and laser sintering processes 

      Herrero Climent, Mariano; Punset Fuste, Miquel; Molmeneu Trias, Meritxell; Brizuela Velasco, Aritza; Gil Mur, Javier (Multidisciplinary Digital Publishing Institute (MDPI), 2023-01-26)
      Article
      Accés obert
      Realitzat a/amb:   Porto Dental Institute / Universidad Europea Miguel de Cervantes / Universitat Internacional de Catalunya
      Digital dentistry and new techniques for the dental protheses’ suprastructure fabrication have undergone a great evolution in recent years, revolutionizing the quality of dental prostheses. The aim of this work is to ...
    • Early short-term postoperative mechanical failures of current ceramic-on-ceramic bearing total hip arthroplasties 

      Fernández Fairén, Mariano; Torres Pérez, Ana; Pérez Antoñanzas, Román; Punset Fuste, Miquel; Molmeneu Trias, Meritxell; Ortiz Hernández, Mónica; Manero Planella, José María; Gil Mur, Javier (Multidisciplinary Digital Publishing Institute (MDPI), 2020-11-24)
      Article
      Accés obert
      Realitzat a/amb:   Universitat Internacional de Catalunya / Hospital General Universitario Santa Lucía
      Although ceramic-on-ceramic (CoC) bearings have been shown to produce the smallest amount of wear volume in vitro as well as in vivo studies when used for total hip arthroplasties (THA), concerns about the failure of these ...
    • Mechanical properties and in vitro biological response to porous titanium alloys for intervertebrae implants 

      Gil Mur, Francisco Javier; Punset Fuste, Miquel; Guillem Martí, Jordi; Molmeneu Trias, Meritxell; Calero, Jose Antonio (2014-11-01)
      Article
      Accés restringit per política de l'editorial
      The generation of titanium foams is a promising strategy for modifying the mechanical properties of intervertebral reinforcements. Thus, the aim of this study was to compare the in vitro biological response of Ti6Al4V ...
    • Mechanical properties and in vitro biological response to porous titanium alloys prepared for use in intervertebral implants 

      Caparrós Vázquez, Cristina Maria; Guillem Martí, Jordi; Molmeneu Trias, Meritxell; Punset Fuste, Miquel; Calero, J. A.; Gil Mur, Francisco Javier (2014-11-01)
      Article
      Accés restringit per política de l'editorial
      The generation of titanium foams is a promising strategy for modifying the mechanical properties of intervertebral reinforcements. Thus, the aim of this study was to compare the in vitro biological response of Ti6Al4V ...
    • Mechanical properties of CoCr dental-prosthesis restorations made by three manufacturing processes. Influence of the microstructure and topography 

      Padrós, Roberto; Punset Fuste, Miquel; Molmeneu Trias, Meritxell; Brizuela Velasco, Aritza; Herrero Climent, Mariano; Rupérez de Gracia, Elisa; Gil Mur, Francisco Javier (Multidisciplinary Digital Publishing Institute (MDPI), 2020-06-14)
      Article
      Accés obert
      Realitzat a/amb:   Barcelona Dental Institute / Universidad de Oviedo / Universitat Internacional de Catalunya
      The aim of this study is to compare the mechanical properties of three different dental restorations’ manufacturing processes (CADCAM milling, casting and laser sintering) generated by only one laboratory scanner focusing ...
    • Mechanical propertiesand in vitro biological response toporoustitaniumalloysprepared for useinintervertebralimplants 

      Caparrós Vázquez, Cristina Maria; Guillem Martí, Jordi; Molmeneu Trias, Meritxell; Punset Fuste, Miquel; Gil Mur, Francisco Javier (2014-06-16)
      Article
      Accés restringit per política de l'editorial
      The generation of titanium foams is a promising strategy for modifying the mechanical properties of intervertebral reinforcements. Thus, the aim of this study was to compare the in vitro biological response of Ti6Al4V ...
    • On-growth and in-growth osseointegration enhancement in PM porous Ti-scaffolds by two different bioactivation strategies: alkali thermochemical treatment and RGD peptide coating 

      Steffaine Rappe, Katrin; Ortiz Hernández, Mónica; Punset Fuste, Miquel; Molmeneu Trias, Meritxell; Barba Serrahima, Albert; Mas Moruno, Carlos; Guillem Martí, Jordi; Caparrós, Cristina; Rupérez de Gracia, Elisa; Calero, José; Manzanares, Maria Cristina; Gil Mur, Javier; Franch, Jordi (2022-02-01)
      Article
      Accés obert
      Realitzat a/amb:   Universitat Autònoma de Barcelona / Institut de Recerca Sant Joan de Déu / AMES / Universitat de Barcelona / Universitat Internacional de Catalunya
      A lack of primary stability and osteointegration in metallic implants may result in implant loosening and failure. Adding porosity to metallic implants reduces the stress shielding effect and improves implant performance, ...
    • Two different strategies to enhance osseointegration in porous titanium: Inorganic thermo-chemical treatment versus organic coating by peptide adsorption 

      Ortiz Hernández, Mónica; Rappe, K.; Molmeneu Trias, Meritxell; Mas Moruno, Carlos; Guillem Martí, Jordi; Punset Fuste, Miquel; Caparrós, Cristina; Calero Martínez, José Antonio; Franch, Jordi; Fernández Fairén, Mariano; Gil, Javier (2018-08-30)
      Article
      Accés obert
      In this study, highly-interconnected porous titanium implants were produced by powder sintering with different porous diameters and open interconnectivity. The actual foams were produced using high cost technologies: ...
    • Zirconia vs. titanium dental implants: primary stability in-vitro analysis 

      Arlucea, Nerea; Brizuela Velasco, Aritza; Diéguez Pereira, Markel; Punset Fuste, Miquel; Molmeneu Trias, Meritxell; Sánchez Lasheras, Fernando; De Llanos Lanchares, Hector; Álvarez Arenal, Ángel (Multidisciplinary Digital Publishing Institute (MDPI), 2021-12-20)
      Article
      Accés obert
      Realitzat a/amb:   Universidad de Oviedo / Instituto Universitario de Ciencias y Tecnologías Espaciales de Asturias (ICTEA)
      The present experimental trial uses two types of dental implants, one made of titanium (Ti6Al4V) and the other one of zirconia (ZrO2), but both of identical design, to compare their stability and micro-movements values ...