<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:itunes="http://www.itunes.com/dtds/podcast-1.0.dtd" xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
  <channel>
    <title>DSpace Collection:</title>
    <link>http://hdl.handle.net/2099/8252</link>
    <description />
    <pubDate>Thu, 23 May 2013 23:38:30 GMT</pubDate>
    <dc:date>2013-05-23T23:38:30Z</dc:date>
    <itunes:owner>
      <itunes:email>webmaster.bupc@upc.edu</itunes:email>
      <itunes:name>Universitat Politècnica de Catalunya. Servei de Biblioteques i Documentació</itunes:name>
    </itunes:owner>
    <itunes:explicit>no</itunes:explicit>
    <itunes:keywords />
    <item>
      <title>Análisis biomecánico de la técnica individual de los finalistas masculinos del lanzamiento de peso en el Campeonato del Mundo de Atletismo Valencia 08</title>
      <link>http://hdl.handle.net/2099/12291</link>
      <description>Title: Análisis biomecánico de la técnica individual de los finalistas masculinos del lanzamiento de peso en el Campeonato del Mundo de Atletismo Valencia 08
Authors: Rojas, F.J.; Gutiérrez-Dávila, M.; Campos, J.; Gámez, J.; Encarnación, A.
Abstract: El objetivo de este estudio ha sido realizar un análisis descriptivo de la técnica individual de los ocho finalistas masculinos de lanzamiento de peso en el Campeonato del Mundo de Atletismo de Pista Cubierta, celebrado en Valencia, 2008. Para este estudio, se han utilizado técnicas fotogramétricas tridimensionales (3D) a partir de la filmación del gesto con dos cámaras de video sincronizadas temporalmente a 100 Hz, analizándose el mejor lanzamiento de cada atleta. Se parte de un análisis temporal, donde se ha dividido el gesto en seis fases. A partir de esas fases, se describen las gráficas de velocidad tangencial del CG y el peso con respecto al tiempo. A continuación, se registraron los factores que determinan la trayectoria del peso durante el vuelo (factores de producto), así como el compromiso de otros factores causales que determinan la eficacia del lanzamiento de peso. Además de confirmar la relación entre los factores de producto, los resultados ponen de manifiesto  que cada lanzador utiliza una secuencia temporal y ritmo de ejecución propio e individual, confirmándose que la ejecución técnica del lanzamiento de peso es individual y está condicionada por características antropométricas, capacidad muscular y el grado de automatización de la secuencia temporal individual.; The aim of this study is to make a descriptive analysis of the individual technique of the eight men finalists in the shot put in the 2008 Valencia Indoor World Championships. To do this three-dimensional photogrammetric techniques (3D) were used, filming the action with two video cameras temporally synchronized at 100 Hz. Six puts were recorded during the men’s final, subsequently analysing the longest throw of each putter. A temporal analysis was first made, dividing the throwing action into six phases. Starting from these phases, graphs of the tangential velocity of the thrower’s CG and the time taken in the shot are described. Then the factors that determine the trajectory of the shot during flight (product factors) and the contribution of the other causal factors for the efficiency of the put are recorded. As well as confirming the relation between the product factors, the results show that each thrower uses his/her own temporal sequence and rhythm of execution, confirming that the technical execution of the shot put is individual and conditioned by anthropometrical characteristics, muscular capacity and the degree of automation of the individual temporal sequence.</description>
      <pubDate>Mon, 01 Jun 2009 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://hdl.handle.net/2099/12291</guid>
      <dc:date>2009-06-01T00:00:00Z</dc:date>
      <itunes:author>Rojas, F.J.; Gutiérrez-Dávila, M.; Campos, J.; Gámez, J.; Encarnación, A.</itunes:author>
      <itunes:explicit>no</itunes:explicit>
      <itunes:keywords>Análisis cinematico tridimensional</itunes:keywords>
      <itunes:summary>El objetivo de este estudio ha sido realizar un análisis descriptivo de la técnica individual de los ocho finalistas masculinos de lanzamiento de peso en el Campeonato del Mundo de Atletismo de Pista Cubierta, celebrado en Valencia, 2008. Para este estudio, se han utilizado técnicas fotogramétricas tridimensionales (3D) a partir de la filmación del gesto con dos cámaras de video sincronizadas temporalmente a 100 Hz, analizándose el mejor lanzamiento de cada atleta. Se parte de un análisis temporal, donde se ha dividido el gesto en seis fases. A partir de esas fases, se describen las gráficas de velocidad tangencial del CG y el peso con respecto al tiempo. A continuación, se registraron los factores que determinan la trayectoria del peso durante el vuelo (factores de producto), así como el compromiso de otros factores causales que determinan la eficacia del lanzamiento de peso. Además de confirmar la relación entre los factores de producto, los resultados ponen de manifiesto  que cada lanzador utiliza una secuencia temporal y ritmo de ejecución propio e individual, confirmándose que la ejecución técnica del lanzamiento de peso es individual y está condicionada por características antropométricas, capacidad muscular y el grado de automatización de la secuencia temporal individual.</itunes:summary>
    </item>
    <item>
      <title>Optimization of a new Ni-free Ti alloy for applications in the implant field</title>
      <link>http://hdl.handle.net/2099/12290</link>
      <description>Title: Optimization of a new Ni-free Ti alloy for applications in the implant field
Authors: González, M.; Arciniegas, M.; Gil, F.J.; Peña, J.; Manero, J.M.
Abstract: Three new Ni-free Ti alloys, Ti-16.2Hf-24.8Nb-1Zr, Ti-5.2Hf-31.2Nb-0.4Zr and Ti-16Hf-36.2Nb-1Zr (wt%), were designed and produced in order to obtain shape memory and/or low elastic modulus materials in order to avoid stress shielding and to enhance bone regeneration in the load transfer implant field. The alloys were microstructurally and mechanically characterized, cytotoxicity was evaluated using MG63 osteoblast-like cells. The elastic modulus of the new alloys (between 67-90 GPa) are smaller than those of the commercial alloys employed for implantation. The lowest elastic modulus alloy, Ti-16.2Hf-24.8Nb-1Zr (wt %), with 67.5 GPa, was optimized by cold work in order to determine the key factor that promotes the desired shape memory properties and/or low elastic modulus.&#xD;
A higher proportion of martensite was observed by optical and electron transmission microscopy in the low cold work samples compared to the quenched alloy. The elastic modulus for each cold work condition was evaluated by nanoindentation tests using a spherical tip. The elastic modulus decreases when increasing the cold work level. The lowest value corresponds to the 99% cold work condition, with 44 GPa, closer to that of cortical bone and smaller than the quenched alloy (67.5 GPa).; Tres nuevas aleaciones de Ti libres de Ni, Ti-16.2Hf-24.8Nb-1Zr, Ti-5.2Hf-31.2Nb-0.4Zr y Ti-16Hf-36.2Nb-1Zr, porcentajes en peso, fueron diseñadas y fabricadas con el fin de obtener memoria de forma y/o bajo módulo elástico con el objetivo de evitar el apantallamiento de cargas y mejorar&#xD;
la regeneración ósea en el campo de la implantología de transferencia de carga. Las aleaciones fueron caracterizadas microestructural y mecánicamente y la citotoxicidad fue evaluada utilizando&#xD;
osteoblastos MG63. El módulo elástico de las nuevas aleaciones (entre 67-90 GPa) es menor que el de las aleaciones comerciales utilizadas en implantología. El menor módulo elástico corresponde a la aleación Ti-16.2Hf-24.8Nb-1Zr, con 67.5 GPa y fue optimizado mediante trabajo en frío con el objetivo de determinar el factor responsable de la obtención de las propiedades deseadas de bajo&#xD;
módulo elástico y/o memoria de forma.&#xD;
Una mayor proporción de martensita fue observada por microscopía óptica y microscopía electrónica de transmisión en las muestras con bajo porcentaje de trabajo en frío en comparación con la muestra templada. El módulo elástico correspondiente a cada condición de trabajo en frío&#xD;
fue evaluado mediante nanoindentación con punta esférica. El módulo elástico disminuye al aumentar el porcentaje de trabajo en frío. El menor valor corresponde a la condición de 95% de trabajo en frío, con 44 GPa, valor cercano al del hueso cortical y  menor que el del material templado (67.5 GPa).</description>
      <pubDate>Mon, 01 Jun 2009 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://hdl.handle.net/2099/12290</guid>
      <dc:date>2009-06-01T00:00:00Z</dc:date>
      <itunes:author>González, M.; Arciniegas, M.; Gil, F.J.; Peña, J.; Manero, J.M.</itunes:author>
      <itunes:explicit>no</itunes:explicit>
      <itunes:keywords>Nanoindentation</itunes:keywords>
      <itunes:summary>Three new Ni-free Ti alloys, Ti-16.2Hf-24.8Nb-1Zr, Ti-5.2Hf-31.2Nb-0.4Zr and Ti-16Hf-36.2Nb-1Zr (wt%), were designed and produced in order to obtain shape memory and/or low elastic modulus materials in order to avoid stress shielding and to enhance bone regeneration in the load transfer implant field. The alloys were microstructurally and mechanically characterized, cytotoxicity was evaluated using MG63 osteoblast-like cells. The elastic modulus of the new alloys (between 67-90 GPa) are smaller than those of the commercial alloys employed for implantation. The lowest elastic modulus alloy, Ti-16.2Hf-24.8Nb-1Zr (wt %), with 67.5 GPa, was optimized by cold work in order to determine the key factor that promotes the desired shape memory properties and/or low elastic modulus.&#xD;
A higher proportion of martensite was observed by optical and electron transmission microscopy in the low cold work samples compared to the quenched alloy. The elastic modulus for each cold work condition was evaluated by nanoindentation tests using a spherical tip. The elastic modulus decreases when increasing the cold work level. The lowest value corresponds to the 99% cold work condition, with 44 GPa, closer to that of cortical bone and smaller than the quenched alloy (67.5 GPa).</itunes:summary>
    </item>
    <item>
      <title>La prótesis Bicontact resultados a 11 años de seguimiento</title>
      <link>http://hdl.handle.net/2099/12289</link>
      <description>Title: La prótesis Bicontact resultados a 11 años de seguimiento
Authors: Curto Gamallo, J.M.; Ramos Pascua, L.; Alonso León, A.; Guiral Eslava, J.; Valentí Ardanuy, J.; Gil Mur, X.; Ferrández Portal, L.</description>
      <pubDate>Mon, 01 Jun 2009 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://hdl.handle.net/2099/12289</guid>
      <dc:date>2009-06-01T00:00:00Z</dc:date>
      <itunes:author>Curto Gamallo, J.M.; Ramos Pascua, L.; Alonso León, A.; Guiral Eslava, J.; Valentí Ardanuy, J.; Gil Mur, X.; Ferrández Portal, L.</itunes:author>
      <itunes:explicit>no</itunes:explicit>
      <itunes:keywords>Prótesis Bicontact</itunes:keywords>
    </item>
    <item>
      <title>Biomechanics of biomaterials used in soft tissue regenerative</title>
      <link>http://hdl.handle.net/2099/12288</link>
      <description>Title: Biomechanics of biomaterials used in soft tissue regenerative
Authors: Vieira, A.F.C.; Vieira, J.M.C.; Marques, A.T.; Guedes, R.M.
Abstract: Biodegradable polymers have been used in implantable medical devices, such as suture fibers, fixation screws and soft tissue engineering devices. Apart from biological compatibility, these devices shall also be functional compatible and perform adequate mechanical temporary support during the healing process. In regenerative medicine, the scaffold that will provide this temporary support should simultaneously enhance cellular adhesion, proliferation and remodeling of new tissue. In soft tissue applications, biodegradable polymers are the materials of election. These materials undergo through a process of degradation, mainly controlled by hydrolysis, leading to a reduction of molecular weight, followed by reduction of strength and finally a reduction of mass until it is totally absorbed and assimilated by the host. Fatigue/creep damage also contribute to the progressive decrease of mechanical properties. Meanwhile, cells cultured over the scaffold will produce the new tissue that will gradually replace the material biomechanical functions.; Os polímeros biodegradáveis têm sido utilizados em dispositivos médicos implantáveis, como fios de sutura, parafusos e dispositivos para engenharia de tecidos moles. Além da compatibilidade biológica, tais dispositivos devem apresentar compatibilidade funcional e desempenhar funções temporárias de suporte mecânico durante o processo de cura. Em medicina regenerativa, este suporte temporário deve favorecer a adesão celular, a sua proliferação e a remodelação de novo tecido. Em engenharia de tecidos moles os polímeros biodegradáveis são os materiais de eleição. Estes materiais sofrem um processo de degradação, controlado sobretudo hidrólise, e que resulta numa redução do peso molecular, seguida de uma redução da resistência mecânica e finalmente uma redução da massa até a completa absorção e assimilação pelo organismo. O dano por fadiga/fluência também contribui para a progressiva diminuição das propriedades mecânicas. Entretanto, as células cultivadas sobre o suporte vão produzir o novo tecido que vai gradualmente substituir as funções biomecânicas do material.</description>
      <pubDate>Mon, 01 Jun 2009 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://hdl.handle.net/2099/12288</guid>
      <dc:date>2009-06-01T00:00:00Z</dc:date>
      <itunes:author>Vieira, A.F.C.; Vieira, J.M.C.; Marques, A.T.; Guedes, R.M.</itunes:author>
      <itunes:explicit>no</itunes:explicit>
      <itunes:keywords />
      <itunes:summary>Biodegradable polymers have been used in implantable medical devices, such as suture fibers, fixation screws and soft tissue engineering devices. Apart from biological compatibility, these devices shall also be functional compatible and perform adequate mechanical temporary support during the healing process. In regenerative medicine, the scaffold that will provide this temporary support should simultaneously enhance cellular adhesion, proliferation and remodeling of new tissue. In soft tissue applications, biodegradable polymers are the materials of election. These materials undergo through a process of degradation, mainly controlled by hydrolysis, leading to a reduction of molecular weight, followed by reduction of strength and finally a reduction of mass until it is totally absorbed and assimilated by the host. Fatigue/creep damage also contribute to the progressive decrease of mechanical properties. Meanwhile, cells cultured over the scaffold will produce the new tissue that will gradually replace the material biomechanical functions.</itunes:summary>
    </item>
    <item>
      <title>Bacterias y su implicación en el fallo de implantes de Titanio</title>
      <link>http://hdl.handle.net/2099/11964</link>
      <description>Title: Bacterias y su implicación en el fallo de implantes de Titanio
Authors: Rodríguez-Hernández, A.G.; Engel, E.; Gil, F.J.</description>
      <pubDate>Fri, 17 Jun 0001 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://hdl.handle.net/2099/11964</guid>
      <dc:date>0001-06-17T00:00:00Z</dc:date>
      <itunes:author>Rodríguez-Hernández, A.G.; Engel, E.; Gil, F.J.</itunes:author>
      <itunes:explicit>no</itunes:explicit>
      <itunes:keywords />
    </item>
    <item>
      <title>La biomecánica en terapia ocupacional</title>
      <link>http://hdl.handle.net/2099/11706</link>
      <description>Title: La biomecánica en terapia ocupacional
Authors: Arráez-Aybar, L.A.
Abstract: La ocupación es una actividad propositiva que desde los tiempos más remotos ha influido en la evolución humana determinando la organización de su tiempo vital. También a lo largo de la historia de la Medicina ha sido utilizada como forma de tratamiento, en la actualidad denominada Terapia Ocupacional. Desde 1917 ha desarrollado una serie de protocolos de actuación en consonancia con el paradigma predominante. Entre ellos se encuentra el Modelo Biomecánico con una vigencia de unos 50 años, aplicable en situaciones disfuncionales de origen ortopédico con integridad del SNC. Este trabajo recoge la ponencia presentada en el XXX Congreso de la SIBB a propuesta del Comité Organizador del mismo y en él se estudia la relación histórica y epistemológica entre la Biomecánica y la Terapia Ocupacional.; The occupation is a propositive activity that from the most remote times has influenced in the human evolution determining the organization of its vital time. Also throughout history of Medicine treatment form has been used as, at the denominated present time Occupational Therapy. From 1917 it has developed a series of protocols of performance in consonancia with the predominant paradigm. Among them is the Biomechanic Model with a use of about 50 years, applicable in orthopaedic/ disfunctional situations of orthopaedic origin with integrity of the SNC. This work gathers the communication presented in the XXX Congress of the SIBB to proposal of the Organizing Committee of the same one. In this paper the historical and epistemologic relation between Biomechanics and the Occupational Therapy studies.</description>
      <pubDate>Mon, 01 Jun 2009 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://hdl.handle.net/2099/11706</guid>
      <dc:date>2009-06-01T00:00:00Z</dc:date>
      <itunes:author>Arráez-Aybar, L.A.</itunes:author>
      <itunes:explicit>no</itunes:explicit>
      <itunes:keywords />
      <itunes:summary>La ocupación es una actividad propositiva que desde los tiempos más remotos ha influido en la evolución humana determinando la organización de su tiempo vital. También a lo largo de la historia de la Medicina ha sido utilizada como forma de tratamiento, en la actualidad denominada Terapia Ocupacional. Desde 1917 ha desarrollado una serie de protocolos de actuación en consonancia con el paradigma predominante. Entre ellos se encuentra el Modelo Biomecánico con una vigencia de unos 50 años, aplicable en situaciones disfuncionales de origen ortopédico con integridad del SNC. Este trabajo recoge la ponencia presentada en el XXX Congreso de la SIBB a propuesta del Comité Organizador del mismo y en él se estudia la relación histórica y epistemológica entre la Biomecánica y la Terapia Ocupacional.</itunes:summary>
    </item>
    <item>
      <title>Obtención de un polímero de tipo Elastina modificado con secuencias Bioactivas y Biodegradables, para su aplicación en ingeniería</title>
      <link>http://hdl.handle.net/2099/11704</link>
      <description>Title: Obtención de un polímero de tipo Elastina modificado con secuencias Bioactivas y Biodegradables, para su aplicación en ingeniería
Authors: García-Arévalo, C.; Girotti, A.; Arias, F.J.; Martín, S.; López, I.M.; Rodríguez-Cabello, J.C.
Abstract: La matriz extracelular es uno de los principales elementos reguladores de la actividad celular. Los diferentes módulos de las macromoléculas que la componen son  capaces de desencadenar señales que activan diferentes rutas intracelulares que organizan las funciones vitales de las células. La ingeniería de tejidos se dedica a desarrollar sistemas capaces de imitar, temporalmente,  el comportamiento de la matriz extracelular con objeto de promover la regeneración o el reemplazo de tejidos y órganos dañados, actuando como un soporte atractivo para las células que deben adherirse y crecer sobre ella, hasta reemplazarla por tejido sano. En este trabajo se describe el proceso de diseño y producción de un polímero de tipo elastina que se ha funcionalizado con secuencias bioactivas que añaden actividades específicas al andamio o soporte celular que constituye la elastina. Así,algunos dominios elastoméricos se modificaron con el aminoácido lisina para poder entrecruzar las moléculas de polímero y conseguir matrices. También se incluyó la secuencia REDV, presente el dominio CS5 de la fibronectina humana, como motivo de adhesión celular. Por último, el polímero se funcionalizó con secuencias diana de enzimas proteolíticas  para mejorar su bioprocesabilidad.; Extracellular matrix (ECM) is a major component for the regulation of cell activity. The different modules of the proteins which constitute the extracellular matrix macromolecules represent for the cells which enter in contact with them, new signals capable of activating several intracellular signaling pathways, resulting in the modulation of numerous cell functions. Tissue engineering tries to develop new materials based on these components as scaffolds for cells to promote their adhesion and growth. In this work, genetic engineering techniques were used to design and biosynthesize an extracellular matrix analogue based in the elastin component. The structural base of our scaffold is an elastin –derived sequence which confers an adequate mechanical behavior. In addition, several domains were included, for adding new bioactivities to this elastin-like polymer (ELP). Some of these elastic domains were modified to contain lysine for cross linking purposes. The polymer also contained periodically spaced fibronectin CS5 domain enclosing the well known cell attachment sequence REDV. Finally, the polymer had target sequences for proteolitic action.</description>
      <pubDate>Mon, 01 Jun 2009 00:00:00 GMT</pubDate>
      <guid isPermaLink="false">http://hdl.handle.net/2099/11704</guid>
      <dc:date>2009-06-01T00:00:00Z</dc:date>
      <itunes:author>García-Arévalo, C.; Girotti, A.; Arias, F.J.; Martín, S.; López, I.M.; Rodríguez-Cabello, J.C.</itunes:author>
      <itunes:explicit>no</itunes:explicit>
      <itunes:keywords>Polimeros de tipo elastina</itunes:keywords>
      <itunes:summary>La matriz extracelular es uno de los principales elementos reguladores de la actividad celular. Los diferentes módulos de las macromoléculas que la componen son  capaces de desencadenar señales que activan diferentes rutas intracelulares que organizan las funciones vitales de las células. La ingeniería de tejidos se dedica a desarrollar sistemas capaces de imitar, temporalmente,  el comportamiento de la matriz extracelular con objeto de promover la regeneración o el reemplazo de tejidos y órganos dañados, actuando como un soporte atractivo para las células que deben adherirse y crecer sobre ella, hasta reemplazarla por tejido sano. En este trabajo se describe el proceso de diseño y producción de un polímero de tipo elastina que se ha funcionalizado con secuencias bioactivas que añaden actividades específicas al andamio o soporte celular que constituye la elastina. Así,algunos dominios elastoméricos se modificaron con el aminoácido lisina para poder entrecruzar las moléculas de polímero y conseguir matrices. También se incluyó la secuencia REDV, presente el dominio CS5 de la fibronectina humana, como motivo de adhesión celular. Por último, el polímero se funcionalizó con secuencias diana de enzimas proteolíticas  para mejorar su bioprocesabilidad.</itunes:summary>
    </item>
  </channel>
</rss>

