Comparative study of high-performance liquid chromatography and micellar electrokinetic capillary chromatography applied to the analysis of different mixtures of pesticides
Visualitza/Obre
Comparative study of high-performance liquid chromatography and micellar electrokinetic capillary chromatography applied to the analysis of different mixtures of .pdf (532,6Kb) (Accés restringit)
Sol·licita una còpia a l'autor
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
10.1016/0021-9673(96)00145-8
Inclou dades d'ús des de 2022
Cita com:
hdl:2117/97806
Tipus de documentArticle
Data publicació1996-06
Condicions d'accésAccés restringit per política de l'editorial
Llevat que s'hi indiqui el contrari, els
continguts d'aquesta obra estan subjectes a la llicència de Creative Commons
:
Reconeixement-NoComercial-SenseObraDerivada 3.0 Espanya
Abstract
High-performance liquid chromatography (HPLC) and micellar electrokinetic capillary chromatography (MECC) methods for the determination of different pesticides mixtures have been developed. These mixtures include triazine, phenylurea, phenoxyalkyl acid, carbamate and organophosphorous pesticides that have been selected because their use in different combinations in commercial formulations. The best results have been obtained by using mobile phase gradients in HPLC and by working with n-alcohols as mobile phase modifiers in MECC. When the quality parameters of both methods have been compared, it was observed that they are not sensitive enough for environmental analysis. In this sense two different concentration methodologies, off-line solid extraction by using Carbopack columns and a special injection MECC method, have been studied to enhance sensitivity. Off-line solid extraction can be used for both HPLC and MECC methodologies and permits to detect low ppb levels of individual pesticides. Special injection methods applied to the MECC system provides a 200-fold sensitivity improvement for the ionic pesticides.
CitacióFarran, A., Ruiz, S., Serra, M., Aguilar, M. Comparative study of high-performance liquid chromatography and micellar electrokinetic capillary chromatography applied to the analysis of different mixtures of pesticides. "Journal of chromatography A", Juny 1996, vol. 737, núm. 1, p. 109-116.
ISSN0021-9673
Col·leccions
- Departament de Teoria del Senyal i Comunicacions - Articles de revista [2.526]
- SETRI - Grup de Tècniques de Separació i Tractament de Residus Industrials - Articles de revista [186]
- WiComTec - Grup de recerca en Tecnologies i Comunicacions Sense Fils - Articles de revista [100]
- Departament d'Enginyeria Química - Articles de revista [2.223]
Fitxers | Descripció | Mida | Format | Visualitza |
---|---|---|---|---|
Comparative stu ... different mixtures of .pdf | 532,6Kb | Accés restringit |