Mostra el registre d'ítem simple

dc.contributor.authorNescolarde Selva, Lexa Digna
dc.contributor.authorDoñate, T.
dc.contributor.authorCasañas Bueno, Roberto
dc.contributor.authorRosell Ferrer, Francisco Javier
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2010-10-01T09:19:16Z
dc.date.available2010-10-01T09:19:16Z
dc.date.created2010
dc.date.issued2010
dc.identifier.citationNescolarde Selva, Lexa. [et al.]. Applications of longitudinal and transversal bioimpedance measurements in peritoneal dialysis at 50 kHz. A: XIVth International Conference on Electrical Bioimpedance. "XIVth International Conference on Electrical Bioimpedance". Gainesville-Florida, April 04-08: 2010, p. 1-4.
dc.identifier.issn1742-6588
dc.identifier.urihttp://hdl.handle.net/2117/9232
dc.description.abstractMore relevant information of the fluid changes in peritoneal dialysis (PD) might be obtained with segmental bioimpedance measurements rather than whole-body measurement, who hidden information of body composition. Whole-body and segmental bioimpedance measurements were obtained using 5 configurations (whole-body or right-side (RS), longitudinal-leg (L-LEG), longitudinal-abdomen (L-AB), transversal-abdomen (T-AB), and transversal-leg (T-LEG)) in 20 patients: 15 males (56.5 ± 9.4 yr, 24.2 ± 4.2 kg/m2) and 5 females (58.4 ± 7.1 yr, 28.2 ± 5.9 kg/m2) in peritoneal dialysis (PD). The aim of this study is to analyze the relationship between whole-body, longitudinal-segmental (L-LEG and L-AB) and transversal-segmental (TAB and TLEG) bioimpedance measurement at 50 kHz, with clinical parameters of cardiovascular risk, dyslipidemia, nutrition and hydration. The Kolmogorov- Smirnov test was used for the normality test of all variables. Longitudinal bioimpedance parameters were normalized by the height of the patients. The Spearman correlation was used to analyze the correlation between bioimpedance and clinical parameters. The statistical significance was considered with P < 0.05. Transversal bioimpedance measurements have higher correlation with clinical parameters than longitudinal measurements.
dc.format.extent4 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica
dc.subject.lcshPeritoneal dialysis
dc.subject.lcshElectronics
dc.titleApplications of longitudinal and transversal bioimpedance measurements in peritoneal dialysis at 50 kHz
dc.typeConference report
dc.subject.lemacElectrònica
dc.contributor.groupUniversitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica
dc.identifier.doi10.1088/1742-6596/224/1/012138
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac2565023
dc.description.versionPostprint (published version)
local.citation.authorNescolarde Selva, Lexa.; Doñate, T.; Casañas, R.; Rosell, F.
local.citation.contributorXIVth International Conference on Electrical Bioimpedance
local.citation.pubplaceGainesville-Florida, April 04-08
local.citation.publicationNameXIVth International Conference on Electrical Bioimpedance
local.citation.startingPage1
local.citation.endingPage4


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple