Mostra el registre d'ítem simple
Optimal sensor placement for leak location in water distribution networks using evolutionary algorithms
dc.contributor.author | Casillas, Myrna V. |
dc.contributor.author | Garza Castañón, Luís Eduardo |
dc.contributor.author | Puig Cayuela, Vicenç |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial |
dc.date.accessioned | 2016-02-18T07:50:59Z |
dc.date.available | 2016-02-18T07:50:59Z |
dc.date.issued | 2015-11-01 |
dc.identifier.citation | Casillas, M., Garza, L., Puig, V. Optimal sensor placement for leak location in water distribution networks using evolutionary algorithms. "Water", 01 Novembre 2015, vol. 7, núm. 11, p. 6496-6515. |
dc.identifier.issn | 2073-4441 |
dc.identifier.uri | http://hdl.handle.net/2117/83085 |
dc.description.abstract | In this paper, a sensor placement approach to improve the leak location in water distribution networks is proposed when the leak signature space (LSS) method is used. The sensor placement problem is formulated as an integer optimization problem where the criterion to be minimized is the number of overlapping signature domains computed from the original LSS representation. First, a semi-exhaustive search approach based on a lazy evaluation mechanism ensures optimal placement in the case of low complexity scenarios. For more complex cases, a stochastic optimization process is proposed, based on either the genetic algorithms (GAs) or particle swarm optimization (PSO). Experiments on two different networks are used to evaluate the performance of the resolution methods, as well as the efficiency achieved in the leak location when using the sensor placement results. |
dc.format.extent | 20 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Informàtica |
dc.subject | Àrees temàtiques de la UPC::Enginyeria civil |
dc.subject.lcsh | Water-supply -- Automatic control |
dc.subject.other | water distribution networks |
dc.subject.other | leak isolation |
dc.subject.other | sensor placement |
dc.subject.other | leak signature space |
dc.subject.other | PARTICLE SWARM OPTIMIZATION |
dc.subject.other | PIPE NETWORKS |
dc.subject.other | DESIGN |
dc.subject.other | METHODOLOGY |
dc.title | Optimal sensor placement for leak location in water distribution networks using evolutionary algorithms |
dc.type | Article |
dc.subject.lemac | Aigua -- Abastament -- Control automàtic |
dc.contributor.group | Universitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control |
dc.identifier.doi | 10.3390/w7116496 |
dc.rights.access | Open Access |
local.identifier.drac | 17509940 |
dc.description.version | Postprint (published version) |
dc.relation.projectid | info:eu-repo/grantAgreement/EC/FP7/318556/EU/Efficient Integrated Real-time Monitoring and Control of Drinking Water Networks/EFFINET |
local.citation.author | Casillas, M.; Garza, L.; Puig, V. |
local.citation.publicationName | Water |
local.citation.volume | 7 |
local.citation.number | 11 |
local.citation.startingPage | 6496 |
local.citation.endingPage | 6515 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [1.390]
-
Articles de revista [507]