Mostra el registre d'ítem simple
Robust sensor placement for leak location: analysis and design
dc.contributor.author | Blesa Izquierdo, Joaquim |
dc.contributor.author | Nejjari Akhi-Elarab, Fatiha |
dc.contributor.author | Sarrate Estruch, Ramon |
dc.contributor.other | Institut de Robòtica i Informàtica Industrial |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial |
dc.date.accessioned | 2016-02-15T11:16:04Z |
dc.date.available | 2016-02-15T11:16:04Z |
dc.date.issued | 2015-09-19 |
dc.identifier.citation | Blesa, J., Nejjari, F., Sarrate, R. Robust sensor placement for leak location: analysis and design. "Journal of hydroinformatics", 19 Setembre 2015, vol. 18, núm. 1, p. 136-148. |
dc.identifier.issn | 1464-7141 |
dc.identifier.uri | http://hdl.handle.net/2117/82915 |
dc.description.abstract | In this paper, a nominal sensor placement methodology for leak location in water distribution networks is presented. To reduce the size and the complexity of the optimization problem a clustering technique is combined with the nominal sensor placement methodology. Some of the pressure sensor placement methods for leak detection and location in water distribution networks are based on the pressure sensitivity matrix analysis. This matrix depends on the network demands, which are nondeterministic, and the leak magnitudes, that are unknown. The robustness of the nominal sensor placement methodology is investigated against the fault sensitivity matrix uncertainty. Providing upon the dependency of the leak location procedure on the network operating point, the nominal sensor placement problem is then reformulated as a multi-objective optimization for which Pareto optimal solutions are generated. The robustness study as well as the resulting robust sensor placement methodology are illustrated by means of a small academic network as well as a district metered area in the Barcelona water distribution network. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Informàtica::Automàtica i control |
dc.subject.lcsh | Detectors |
dc.subject.lcsh | Water - Distribution |
dc.subject.lcsh | Automatic control |
dc.subject.other | clustering |
dc.subject.other | leak location |
dc.subject.other | robustness analysis |
dc.subject.other | sensor placement |
dc.title | Robust sensor placement for leak location: analysis and design |
dc.type | Article |
dc.subject.lemac | Detectors |
dc.subject.lemac | Aigua--Distribució |
dc.subject.lemac | Control automàtic |
dc.contributor.group | Universitat Politècnica de Catalunya. SIC - Sistemes Intel·ligents de Control |
dc.contributor.group | Universitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control |
dc.identifier.doi | 10.2166/hydro.2015.021 |
dc.description.peerreviewed | Peer Reviewed |
dc.relation.publisherversion | http://www.iwaponline.com/jh/up/jh2015021.htm |
dc.rights.access | Open Access |
local.identifier.drac | 16991887 |
dc.description.version | Postprint (published version) |
dc.relation.projectid | info:eu-repo/grantAgreement/EC/FP7/318556/EU/Efficient Integrated Real-time Monitoring and Control of Drinking Water Networks/EFFINET |
local.citation.author | Blesa, J.; Nejjari, F.; Sarrate, R. |
local.citation.publicationName | Journal of hydroinformatics |
local.citation.volume | 18 |
local.citation.number | 1 |
local.citation.startingPage | 136 |
local.citation.endingPage | 148 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [133]
-
Articles de revista [1.397]
-
Articles de revista [509]
-
Articles de revista [376]