Mostra el registre d'ítem simple

dc.contributor.authorAldaba Arévalo, Mikel
dc.contributor.authorGómez López, Selena
dc.contributor.authorVilaseca Ricart, Meritxell
dc.contributor.authorPujol Ramo, Jaume
dc.contributor.authorArjona Carbonell, Mª Montserrat
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Òptica i Optometria
dc.date.accessioned2016-01-12T11:01:15Z
dc.date.available2016-01-12T11:01:15Z
dc.date.issued2015-10-01
dc.identifier.citationAldaba , M., Gómez, S., Vilaseca, M., Pujol, J., Arjona, M. Comparing autorefractors for measurement of accommodation. "Optometry and vision science", 01 Octubre 2015, vol. 92, núm. 10, p. 1003-1011.
dc.identifier.issn1040-5488
dc.identifier.urihttp://hdl.handle.net/2117/81263
dc.description.abstractPurpose To compare the static and dynamic accommodative responses measured with the WAM-5500 and the PowerRef-II autorefractors.; Methods The dynamic and static monocular accommodative responses were measured with the WAM-5500 and the PowerRef-II instruments in 30 pre-presbyopic patients (23.66 [3.19] years). The spherical equivalent was measured at 0.00, 2.50, and 5.00 diopters (D) of accommodative stimulation for the static measurements. The subjective refraction was also determined. Dynamic accommodation was measured for abrupt changes of stimulus vergence of 2.00 D. Mean and peak velocities of accommodation and disaccommodation were evaluated. For the PowerRef-II, dynamic measurements were calculated for sampling frequencies of 5 and 25 Hz.; Results For far distance static results, the differences between subjective and WAM-5500 measurements were 0.07 (+/- 0.21) D (p = 0.093) and those between subjective and PowerRef-II measurements were 0.70 (+/- 0.47) D (p = 0.001). The difference in the response measured with both instruments was 0.08 (+/- 0.32) D (p = 0.194) for 2.50 D and -0.32 (+/- 0.48) D (p = 0.001) for 5.00 D of stimulation. For the dynamic mode, the PowerRef-II at 25 Hz measured faster mean and peak velocities of accommodation and disaccommodation than the WAM-5500, with statistically significant (p < 0.05) differences of 0.68 (+/- 1.01), 0.67 (+/- 0.98), 1.26 (+/- 1.19), and 1.42 (+/- 1.53) D/s, respectively. With a sampling frequency of 5 Hz for the PowerRef-II, these differences, which were statistically significant (p < 0.05), were reduced to 0.52 (+/- 0.90), 0.49 (+/- 0.91), 0.83 (+/- 1.07), and 0.83 (+/- 1.31) D/s, respectively.; Conclusions There is good agreement between subjective refraction and WAM-5500 measurements. In contrast, the PowerRef-II produced more hyperopic results. There were no differences among instruments at 2.50 D of static stimulation; however, differences were found at 5.00 D. In the dynamic measurements, the PowerRef-II measured faster velocities, partly attributed to the difference in the sampling frequency.
dc.format.extent9 p.
dc.language.isoeng
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Ciències de la visió::Optometria::Acomodació i refracció
dc.subject.lcshEye--Accommodation and refraction
dc.subject.lcshPresbyopia
dc.subject.otheraccommodation
dc.subject.otheraccommodative response
dc.subject.otherstatic
dc.subject.otherdynamic
dc.subject.otherWAM-5500
dc.subject.otherPowerRef-II
dc.subject.otherECCENTRIC INFRARED PHOTOREFRACTOR
dc.subject.otherAGE-RELATED-CHANGES
dc.subject.otherCLINICAL-EVALUATION
dc.subject.otherREFRACTIVE ERROR
dc.subject.otherSTATISTICAL-METHODS
dc.subject.otherGRAND SEIKO
dc.subject.otherPOWERREFRACTOR
dc.subject.otherDYNAMICS
dc.subject.otherAGREEMENT
dc.subject.otherWAM-5500
dc.titleComparing autorefractors for measurement of accommodation
dc.typeArticle
dc.subject.lemacUlls -- Acomodació i refracció
dc.subject.lemacPresbícia
dc.contributor.groupUniversitat Politècnica de Catalunya. GREO - Grup de Recerca en Enginyeria Òptica
dc.identifier.doi10.1097/OPX.0000000000000685
dc.rights.accessOpen Access
local.identifier.drac16844913
dc.description.versionPreprint
local.citation.authorAldaba, M.; Gómez, S.; Vilaseca, M.; Pujol, J.; Arjona, M.
local.citation.publicationNameOptometry and vision science
local.citation.volume92
local.citation.number10
local.citation.startingPage1003
local.citation.endingPage1011


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple