Mostra el registre d'ítem simple
Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty
dc.contributor.author | Nejjari Akhi-Elarab, Fatiha |
dc.contributor.author | Sarrate Estruch, Ramon |
dc.contributor.author | Blesa Izquierdo, Joaquim |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial |
dc.coverage.spatial | east=2.1734034999999494; north=41.38506389999999; name=Barcelona, Espanya |
dc.date.accessioned | 2015-10-02T11:13:57Z |
dc.date.available | 2015-10-02T11:13:57Z |
dc.date.issued | 2015 |
dc.identifier.citation | Nejjari, F., Sarrate, R., Blesa, J. Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty. A: Computing and Control for the Water Industry. "CCWI 2015 - Computing and Control for the Water Industry". Leicester: Elsevier, 2015, p. 953-962. |
dc.identifier.isbn | 1877-7058 |
dc.identifier.uri | http://hdl.handle.net/2117/77291 |
dc.description.abstract | In this paper an optimal sensor placement strategy based on pressure sensitivity matrix analysis and an exhaustive search strategy that maximizes some diagnosis specifications for a water distribution network is presented. An average worst leak expansion distance as a new leak location performance measure has been proposed. This metric is later used to assess the leak location uncertainty provided by a sensor configuration. The method is combined with a clustering technique in order to reduce the size and the complexity of the sensor placement problem. The strategy is successfully applied to determine the location of a set of pressure sensors in a district metered area in the Barcelona water distribution network. |
dc.format.extent | 10 p. |
dc.language.iso | eng |
dc.publisher | Elsevier |
dc.subject | Àrees temàtiques de la UPC::Informàtica::Automàtica i control |
dc.subject.lcsh | Detectors |
dc.subject.lcsh | Water - Distribution |
dc.subject.other | sensor placement |
dc.subject.other | leak location |
dc.subject.other | clustering |
dc.title | Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty |
dc.type | Conference report |
dc.subject.lemac | Detectors |
dc.subject.lemac | Aigua--Distribució |
dc.contributor.group | Universitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control |
dc.contributor.group | Universitat Politècnica de Catalunya. SIC - Sistemes Intel·ligents de Control |
dc.identifier.doi | 10.1016/j.proeng.2015.08.979 |
dc.description.peerreviewed | Peer Reviewed |
dc.relation.publisherversion | http://www.sciencedirect.com/science/journal/18777058/119/supp/C |
dc.rights.access | Open Access |
local.identifier.drac | 16920357 |
dc.description.version | Postprint (published version) |
dc.relation.projectid | info:eu-repo/grantAgreement/EC/FP7/318556/EU/Efficient Integrated Real-time Monitoring and Control of Drinking Water Networks/EFFINET |
local.citation.author | Nejjari, F.; Sarrate, R.; Blesa, J. |
local.citation.contributor | Computing and Control for the Water Industry |
local.citation.pubplace | Leicester |
local.citation.publicationName | CCWI 2015 - Computing and Control for the Water Industry |
local.citation.startingPage | 953 |
local.citation.endingPage | 962 |