Mostra el registre d'ítem simple

dc.contributor.authorBrualla Barbera, Lorenzo
dc.contributor.authorPalanco Zamora, R.
dc.contributor.authorWitting, A.
dc.contributor.authorSempau Roma, Josep
dc.contributor.authorSauerwein, W.
dc.contributor.otherUniversitat Politècnica de Catalunya. Institut de Tècniques Energètiques
dc.date.accessioned2010-06-15T10:30:46Z
dc.date.available2010-06-15T10:30:46Z
dc.date.created2009-08
dc.date.issued2009-08
dc.identifier.citationBrualla, L. [et al.]. Comparison between PENELOPE and electron Monte Carlo simulations of electron fields used in the treatment of conjunctival lymphoma. "Physics in medicine and biology", Agost 2009, vol. 54, núm. 18, p. 5469-5481.
dc.identifier.issn0031-9155
dc.identifier.urihttp://hdl.handle.net/2117/7669
dc.description.abstractFor the treatment of conjunctival lymphoma in the early stages, external beam radiotherapy offers a curative approach. Such treatment requires the use of highly conformed small radiation beams. The beam size is so small that even advanced treatment planning systems have difficulties in calculating dose distributions. One possible approach for optimizing the treatment technique and later performing treatment planning is by means of full Monte Carlo (MC) simulations. In this paper, we compare experimental absorbed dose profiles obtained with a collimator used at the University Hospital Essen, with MC simulations done with the general-purpose radiation transport code PENELOPE. The collimator is also simulated with the hybrid MC code electron Monte Carlo (eMC) implemented in the commercial treatment planning system Eclipse (Varian). The results obtained with PENELOPE have a maximum difference with experimental data of 2.3%, whereas the eMC code differs systematically from the experimental data about 7% in the penumbra tails. We also show that PENELOPE simulations are able to obtain absorbed dose maps with an equivalent statistical uncertainty to the one found with eMC in similar CPU times.
dc.format.extent13 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Física::Electromagnetisme
dc.subjectÀrees temàtiques de la UPC::Enginyeria biomèdica::Electrònica biomèdica
dc.subject.lcshMonte Carlo method
dc.subject.lcshMedical physics
dc.titleComparison between PENELOPE and electron Monte Carlo simulations of electron fields used in the treatment of conjunctival lymphoma
dc.typeArticle
dc.subject.lemacMonte Carlo, Mètode de
dc.subject.lemacFísica mèdica
dc.contributor.groupUniversitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions
dc.identifier.doi10.1088/0031-9155/54/18/008
dc.relation.publisherversionhttp://iopscience.iop.org/0031-9155/54/18/008/?ejredirect=.iopscience
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac2044667
dc.description.versionPostprint (published version)
local.citation.authorBrualla, L.; Palanco, R.; Witting, A.; Sempau, J.; Sauerwein, W.
local.citation.publicationNamePhysics in medicine and biology
local.citation.volume54
local.citation.number18
local.citation.startingPage5469
local.citation.endingPage5481


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple