Mostra el registre d'ítem simple

dc.contributor.authorLópez Grimau, Víctor
dc.contributor.authorGutiérrez Bouzán, María Carmen
dc.contributor.authorGriera, J
dc.contributor.authorGuadayol Cunill, José María
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Química
dc.contributor.otherUniversitat Politècnica de Catalunya. Institut d'Investigació Tèxtil i Cooperació Industrial de Terrassa
dc.date.accessioned2010-05-21T09:26:31Z
dc.date.available2010-05-21T09:26:31Z
dc.date.created2006-01
dc.date.issued2006-01
dc.identifier.citationLópez-Grimau, V. [et al.]. Determination of non halogenated solvents in industrial wastewater using solid phase microextraction (SPME) and GC-MS. "Latin american applied research", Gener 2006, vol. 36, núm. 1, p. 49-55.
dc.identifier.issn0327-0793
dc.identifier.urihttp://hdl.handle.net/2117/7351
dc.description.abstractSolid phase microextraction (SPME) was applied to the analysis of a selected group of non halogenated solvents -all of them classified as volatile organic compounds (VOCs)- that may be present in diverse industrial wastewaters. Two different fibres (100-PDMS and 85-PA) were selected as SPME adsorbents. The extracted volatile organic compounds were analysed by high resolution gas chromatography coupled to mass spectrometry (GC-MS), following the EPA method 624. Calibration curves and method deletion limits obtained for these solvents using the two SPME fibres are reported. The 100-PDMS fibre provided better sensitivity, but the saturation was reached at a lower concentration than 85-PA fibre. The first fibre (100-PDMS) was applied to the analysis of several textile wastewaters. The method detection limits obtained with this fibre were: 0.1-0.3 μ/L for ethylbenzene m-xylene p-xylene toluene and diisobutyl ketone. In addition SPME and Headspace (HS) detection limits were compared.
dc.format.extent7 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Indústries químiques
dc.subject.lcshSolvents -- Analysis.
dc.subject.lcshWastewater treatment and reuse
dc.titleDetermination of non halogenated solvents in industrial wastewater using solid phase microextraction (SPME) and GC-MS
dc.typeArticle
dc.subject.lemacAigües residuals -- Anàlisi
dc.subject.lemacDissolvents -- Aspectes ambientals
dc.contributor.groupUniversitat Politècnica de Catalunya. ENMA - Enginyeria del Medi Ambient
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://www.laar.uns.edu.ar/indexes/artic_v3601/Vol_36_1_pp49.pdf
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac684155
dc.description.versionPostprint (published version)
local.citation.authorLópez-Grimau, V.; Gutiérrez, M.; Griera, J.; Guadayol, J.
local.citation.publicationNameLatin american applied research
local.citation.volume36
local.citation.number1
local.citation.startingPage49
local.citation.endingPage55


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple