Mostra el registre d'ítem simple
RR time series comparison obtained by H7 polar sensors or by photoplethysmography using smartphones: breathing and devices influences
dc.contributor.author | Mateu Mateus, Marc |
dc.contributor.author | Guede Fernández, Federico |
dc.contributor.author | García González, Miguel Ángel |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica |
dc.date.accessioned | 2015-03-26T11:07:28Z |
dc.date.created | 2014 |
dc.date.issued | 2014 |
dc.identifier.citation | Mateu, M.; Guede, F.; Garcia, M. RR time series comparison obtained by H7 polar sensors or by photoplethysmography using smartphones: breathing and devices influences. A: European Conference of the International Federation for Medical and Biological Engineering. "IFMBE Proceedings volume 45 - 6th European Conference of the International Federation for Medical an Biological Engineering (MBEC 2014)". Dubrownik: Springer, 2014, p. 264-267. |
dc.identifier.isbn | 978-3-319-11127-8 |
dc.identifier.uri | http://hdl.handle.net/2117/27045 |
dc.description.abstract | This work compares the time series obtained by measuring simultaneously the RR time series with a Polar Sensor and the Pulse to Pulse (PP) time series by using the camera of smartphones. The measured differences between time series are modulated by the breathing rate and have little influence from the measuring device. The standard deviation of the differences between time series depends mostly on the subject under measurement and can change from values of around 10 ms order to values near 100 ms. These differences affect the quantification of HRV. On average, a breathing rate around 0.2 Hz is advised to minimize these errors. |
dc.format.extent | 4 p. |
dc.language.iso | eng |
dc.publisher | Springer |
dc.subject | Àrees temàtiques de la UPC::Enginyeria biomèdica::Electrònica biomèdica |
dc.subject.lcsh | Heart beat |
dc.subject.lcsh | Respiration |
dc.subject.lcsh | Smartphones |
dc.subject.other | Heart rate variability |
dc.subject.other | Pulse Transit Time |
dc.subject.other | Smartphone application |
dc.subject.other | Non-invasive Measurement. |
dc.title | RR time series comparison obtained by H7 polar sensors or by photoplethysmography using smartphones: breathing and devices influences |
dc.type | Conference report |
dc.subject.lemac | Respiració |
dc.subject.lemac | Cor |
dc.subject.lemac | Telèfons intel·ligents |
dc.contributor.group | Universitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica |
dc.identifier.doi | 10.1007/978-3-319-11128-5_66 |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 15178010 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Mateu, M.; Guede, F.; Garcia, M. |
local.citation.contributor | European Conference of the International Federation for Medical and Biological Engineering |
local.citation.pubplace | Dubrownik |
local.citation.publicationName | IFMBE Proceedings volume 45 - 6th European Conference of the International Federation for Medical an Biological Engineering (MBEC 2014) |
local.citation.startingPage | 264 |
local.citation.endingPage | 267 |