Mostra el registre d'ítem simple
Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters
dc.contributor.author | Sanchez, R. M. |
dc.contributor.author | Vano, E |
dc.contributor.author | Fernández, J. M. |
dc.contributor.author | Ginjaume Egido, Mercè |
dc.contributor.author | Duch Guillen, María Amor |
dc.contributor.other | Universitat Politècnica de Catalunya. Institut de Tècniques Energètiques |
dc.date.accessioned | 2015-03-11T11:13:16Z |
dc.date.available | 2015-03-11T11:13:16Z |
dc.date.created | 2014-12-01 |
dc.date.issued | 2014-12-01 |
dc.identifier.citation | Sanchez, R. [et al.]. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters. "Radiation protection dosimetry", 01 Desembre 2014, vol. 162, núm. 4, p. 569-576. |
dc.identifier.issn | 0144-8420 |
dc.identifier.uri | http://hdl.handle.net/2117/26661 |
dc.description.abstract | The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of 215% vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to +/- 20% versus TLD. With dosemeters positioned outside the goggles and when TLD doses were > 20 mu Sv, the average difference OSL vs. TLD was 29%. Eye lens doses of almost 700 mu Sv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey. |
dc.format.extent | 8 p. |
dc.language.iso | eng |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Spain |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Física::Electromagnetisme |
dc.subject | Àrees temàtiques de la UPC::Ciències de la salut::Medicina::Cirurgia |
dc.subject | Àrees temàtiques de la UPC::Ciències de la salut::Medicina::Diagnòstic per la imatge |
dc.subject.lcsh | Cardiology |
dc.subject.lcsh | Radiation dosimetry |
dc.subject.other | Personal dosimeters |
dc.subject.other | Radiation-exposure |
dc.subject.other | Medical staff |
dc.subject.other | Radiology |
dc.subject.other | Catheterization |
dc.subject.other | Lif-mg |
dc.subject.other | cu |
dc.subject.other | p |
dc.subject.other | Operators |
dc.title | Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters |
dc.type | Article |
dc.subject.lemac | Radiació--Dosimetria |
dc.subject.lemac | Cardiologia |
dc.contributor.group | Universitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions |
dc.identifier.doi | 10.1093/rpd/nct368 |
dc.rights.access | Open Access |
local.identifier.drac | 15446953 |
dc.description.version | Postprint (published version) |
local.citation.author | Sanchez, R.; Vano, E.; Fernández, J.; Ginjaume, M.; Duch, M. |
local.citation.publicationName | Radiation protection dosimetry |
local.citation.volume | 162 |
local.citation.number | 4 |
local.citation.startingPage | 569 |
local.citation.endingPage | 576 |