Closed-loop actuator-fault detection and isolation using invariant set and tubes
dc.contributor.author | Xu, Feng |
dc.contributor.author | Puig Cayuela, Vicenç |
dc.contributor.author | Ocampo-Martínez, Carlos |
dc.contributor.author | Stoican, Florin |
dc.contributor.author | Olaru, Sorin |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial |
dc.date.accessioned | 2014-11-13T11:23:03Z |
dc.date.created | 2014 |
dc.date.issued | 2014 |
dc.identifier.citation | Xu, F. [et al.]. Closed-loop actuator-fault detection and isolation using invariant set and tubes. A: World Congress of the International Federation of Automatic Control. "Proceedings of the 19th IFAC World Congress, 2014". Cape Town: 2014, p. 8030-8035. |
dc.identifier.uri | http://hdl.handle.net/2117/24713 |
dc.description.abstract | This paper proposes a new actuator-fault detection and isolation (FDI) strategy for closed-loop discrete time-invariant systems by using invariant sets and tubes. In this approach, invariant sets are used for fault detection (FD) and the establishment of FDI conditions, while the tubes are generated for fault isolation (FI) at transient state. Comparing with the existing set-theoretic FDI techniques, the advantage of this approach consists in that it exhibits a balance between the conservativeness of FDI conditions, the fast FI response and the computational complexity. The eectiveness of the proposed technique is illustrated by a numerical example. |
dc.format.extent | 6 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Informàtica::Automàtica i control |
dc.subject.lcsh | Tolerance (Engineering) |
dc.subject.other | control system analysis |
dc.subject.other | control theory |
dc.subject.other | observability |
dc.subject.other | fault detection and isolation |
dc.subject.other | invariant sets |
dc.subject.other | zonotopes |
dc.title | Closed-loop actuator-fault detection and isolation using invariant set and tubes |
dc.type | Conference report |
dc.subject.lemac | Tolerància (Enginyeria) |
dc.contributor.group | Universitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control |
dc.identifier.doi | 10.3182/20140824-6-ZA-1003.01653 |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 15271419 |
dc.description.version | Postprint (published version) |
dc.relation.projectid | info:eu-repo/grantAgreement/EC/FP7/270428/EU/Making Sense of Nonsense/ISENSE |
dc.date.lift | 10000-01-01 |
local.citation.author | Xu, F.; Puig, V.; Ocampo-Martinez, C.A.; Stoican, F.; Olaru, S. |
local.citation.contributor | World Congress of the International Federation of Automatic Control |
local.citation.pubplace | Cape Town |
local.citation.publicationName | Proceedings of the 19th IFAC World Congress, 2014 |
local.citation.startingPage | 8030 |
local.citation.endingPage | 8035 |