Mostra el registre d'ítem simple
Optimal sensor placement for leakage detection and isolation in water distribution networks
dc.contributor.author | Rosich Oliva, Albert |
dc.contributor.author | Sarrate Estruch, Ramon |
dc.contributor.author | Nejjari Akhi-Elarab, Fatiha |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial |
dc.date.accessioned | 2014-05-26T10:12:37Z |
dc.date.created | 2012 |
dc.date.issued | 2012 |
dc.identifier.citation | Rosich, A.; Sarrate, R.; Nejjari, F. Optimal sensor placement for leakage detection and isolation in water distribution networks. A: IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes. "SAFEPROCESS 2012. 8th IFAC International Symposium on Fault Detection, Supervision and Safety for Technical Processes". Mexico City: 2012, p. 776-781. |
dc.identifier.uri | http://hdl.handle.net/2117/23047 |
dc.description.abstract | In this paper, the problem of leakage detection and isolation in water distribution networks is addressed applying an optimal sensor placement methodology. The chosen technique is based on structural models and thus it is suitable to handle non-linear and large scale systems. A drawback of this technique arises when costs are assigned uniformly. A main contribution of this paper is the proposal of an iterative methodology that focuses on identifying essential sensors which ultimately leads to an improvement of the optimal search efficiency. The algorithm presented in this work is successfully applied to a District Metered Area (DMA) in the Barcelona water distribution network. |
dc.format.extent | 6 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Informàtica::Automàtica i control |
dc.subject.lcsh | Detectors |
dc.subject.lcsh | Automatic control |
dc.subject.lcsh | Municipal water supply--Barcelona |
dc.title | Optimal sensor placement for leakage detection and isolation in water distribution networks |
dc.type | Conference report |
dc.subject.lemac | Detectors |
dc.subject.lemac | Control automàtic |
dc.subject.lemac | Aigua--Abastament urbà--Barcelona (Catalunya) |
dc.contributor.group | Universitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control |
dc.contributor.group | Universitat Politècnica de Catalunya. SIC - Sistemes Intel·ligents de Control |
dc.identifier.doi | 10.3182/20120829-3-MX-2028.00232 |
dc.description.peerreviewed | Peer Reviewed |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 11021021 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Rosich, A.; Sarrate, R.; Nejjari, F. |
local.citation.contributor | IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes |
local.citation.pubplace | Mexico City |
local.citation.publicationName | SAFEPROCESS 2012. 8th IFAC International Symposium on Fault Detection, Supervision and Safety for Technical Processes |
local.citation.startingPage | 776 |
local.citation.endingPage | 781 |