Mostra el registre d'ítem simple
High-accuracy determination of the neutron flux at n TOF
dc.contributor.author | Barbagallo, M. |
dc.contributor.author | Guerrero, C. |
dc.contributor.author | Tsinganis, A. |
dc.contributor.author | Tarrío, D. |
dc.contributor.author | Altstadt, S. |
dc.contributor.author | Andriamonje, S. |
dc.contributor.author | Andrzejewski, J. |
dc.contributor.author | Audouin, L. |
dc.contributor.author | Bécares, V. |
dc.contributor.author | Becvar, F. |
dc.contributor.author | Belloni, Fabio |
dc.contributor.author | Calviño Tavares, Francisco |
dc.contributor.author | Cortés Rossell, Guillem Pere |
dc.contributor.author | Gómez Hornillos, María Belén |
dc.contributor.author | Hernández-Prieto, A. |
dc.contributor.author | Riego Pérez, Albert |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament de Física i Enginyeria Nuclear |
dc.date.accessioned | 2014-01-27T10:38:15Z |
dc.date.created | 2013-12-18 |
dc.date.issued | 2013-12-18 |
dc.identifier.citation | Barbagallo, M. [et al.]. High-accuracy determination of the neutron flux at n TOF. "European physical journal A", 18 Desembre 2013, vol. 49, núm. 12, p. 15601-15611. |
dc.identifier.issn | 1434-6001 |
dc.identifier.uri | http://hdl.handle.net/2117/21365 |
dc.description.abstract | The neutron flux of the n TOF facility at CERN was measured, after installation of the new spallation target, with four different systems based on three neutron-converting reactions, which represent accepted cross sections standards in different energy regions. A careful comparison and combination of the different measurements allowed us to reach an unprecedented accuracy on the energy dependence of the neutron flux in the very wide range (thermal to 1 GeV) that characterizes the n TOF neutron beam. This is a pre-requisite for the high accuracy of cross section measurements at n TOF. An unexpected anomaly in the neutron-induced fission cross section of 235U is observed in the energy region between 10 and 30 keV, hinting at a possible overestimation of this important cross section, well above currently assigned uncertainties. |
dc.format.extent | 11 p. |
dc.language.iso | eng |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Spain |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Energies::Energia nuclear |
dc.subject | Àrees temàtiques de la UPC::Física |
dc.subject.lcsh | Neutrons |
dc.subject.lcsh | High pressure physics |
dc.subject.other | Neutron |
dc.subject.other | Experimental physics |
dc.subject.other | Ntof |
dc.subject.other | Flux |
dc.subject.other | CERN |
dc.title | High-accuracy determination of the neutron flux at n TOF |
dc.type | Article |
dc.subject.lemac | Neutrons |
dc.contributor.group | Universitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions |
dc.identifier.doi | 10.1140/epja/i2013-13156-x |
dc.relation.publisherversion | http://epja.epj.org/articles/epja/abs/2013/12/10050_2013_Article_9988/10050_2013_Article_9988.html |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 12935092 |
dc.description.version | Postprint (published version) |
dc.relation.projectid | info:eu-repo/grantAgreement/EC/FP7/249671/EU/Accurate Nuclear Data for nuclear Energy Sustainability/ANDES |
dc.date.lift | 10000-01-01 |
local.citation.author | Barbagallo, M.; Guerrero, C.; Tsinganis, A.; Tarrío, D.; Altstadt , S.; Andriamonje, S.; Andrzejewski, J.; Audouin, L.; Bécares , V.; Becvar, F.; Belloni, F.; Calviño, F.; Cortes, G.; Gómez-Hornillos, M.B.; Hernández-Prieto, A.; Riego, A. |
local.citation.publicationName | European physical journal A |
local.citation.volume | 49 |
local.citation.number | 12 |
local.citation.startingPage | 15601 |
local.citation.endingPage | 15611 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [603]
-
Articles de revista [178]