Mostra el registre d'ítem simple
Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor
dc.contributor.author | Vilaseca Ricart, Meritxell |
dc.contributor.author | Arjona Carbonell, Mª Montserrat |
dc.contributor.author | Pujol Ramo, Jaume |
dc.contributor.author | Peris March, María Elvira |
dc.contributor.author | Martínez Rodríguez, Vanessa |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Òptica i Optometria |
dc.date.accessioned | 2014-01-23T11:43:20Z |
dc.date.available | 2014-01-23T11:43:20Z |
dc.date.created | 2013-10-18 |
dc.date.issued | 2013-10-18 |
dc.identifier.citation | Vilaseca, M. [et al.]. Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor. "International Journal of Ophthalmology", 18 Octubre 2013, vol. 6, núm. 5, p. 618-625. |
dc.identifier.issn | 2222-3959 |
dc.identifier.uri | http://hdl.handle.net/2117/21333 |
dc.format.extent | 8 p. |
dc.language.iso | eng |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Spain |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Ciències de la visió::Optometria::Acomodació i refracció |
dc.subject.lcsh | Quality control--Optical methods |
dc.subject.lcsh | Retinoscopy |
dc.subject.lcsh | Refraction |
dc.subject.lcsh | Eye--Accommodation and refraction |
dc.subject.other | double-pass system |
dc.subject.other | optical quality |
dc.subject.other | retinoscopy |
dc.subject.other | autorefraction |
dc.subject.other | subjective refraction |
dc.subject.other | accuracy |
dc.subject.other | repeatability |
dc.subject.other | trueness |
dc.title | Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor |
dc.type | Article |
dc.subject.lemac | Retinoscopia |
dc.subject.lemac | Ulls -- Acomodació i refracció |
dc.contributor.group | Universitat Politècnica de Catalunya. GREO - Grup de Recerca en Enginyeria Òptica |
dc.contributor.group | Universitat Politècnica de Catalunya. GRCUV - Grup de Recerca del Centre Universitari de la Visió |
dc.identifier.doi | 10.3980/j.issn.2222-3959.2013.05.12 |
dc.rights.access | Open Access |
local.identifier.drac | 12914176 |
dc.description.version | Postprint (published version) |
local.citation.author | Vilaseca, M.; Arjona, M.; Pujol, J.; Peris, M. Elvira; Martínez, V. |
local.citation.publicationName | International Journal of Ophthalmology |
local.citation.volume | 6 |
local.citation.number | 5 |
local.citation.startingPage | 618 |
local.citation.endingPage | 625 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [72]
-
Articles de revista [149]
-
Articles de revista [447]