Mostra el registre d'ítem simple

dc.contributor.authorSánchez Terrones, Benjamín
dc.contributor.authorVandersteen, Gerd
dc.contributor.authorMartín Robles, Irene
dc.contributor.authorCastillo Villegas, Diego
dc.contributor.authorTorrego Fernández, Alfons
dc.contributor.authorRiu Costa, Pere Joan
dc.contributor.authorSchoukens, Johan
dc.contributor.authorBragós Bardia, Ramon
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2013-09-25T15:23:22Z
dc.date.created2013-07
dc.date.issued2013-07
dc.identifier.citationSánchez, B. [et al.]. In vivo electrical bioimpedance characterization of human lung tissue during the bronchoscopy procedure. A feasibility study. "Medical engineering and physics", Juliol 2013, vol. 35, núm. 7, p. 949-957.
dc.identifier.issn1350-4533
dc.identifier.urihttp://hdl.handle.net/2117/20212
dc.description.abstractLung biopsies form the basis for the diagnosis of lung cancer. However, in a significant number of cases bronchoscopic lung biopsies fail to provide useful information, especially in diffuse lung disease, so more aggressive procedures are required. Success could be improved using a guided electronic biopsy based on multisine electrical impedance spectroscopy (EIS), a technique which is evaluated in this paper. The theoretical basis of the measurement method and the instrument developed are described, characterized and calibrated while the performance of the instrument is assessed by experiments to evaluate the noise and nonlinear source of errors from measurements on phantoms. Additional preliminary results are included to demonstrate that it is both feasible and safe to monitor in vivo human lung tissue electrical bioimpedance (EBI) during the bronchoscopy procedure. The time required for performing bronchoscopy is not extended because the bioimpedance measurements, present no complications, tolerance problems or side effects among any of the patients measured.
dc.format.extent9 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica
dc.subjectÀrees temàtiques de la UPC::Ciències de la salut::Medicina
dc.subject.lcshBiomedical & nanomedical technologies
dc.subject.lcshSpectrum analysis.
dc.subject.lcshBronchoscopy
dc.subject.otherBroadband electrical impedance spectroscopy (EIS)
dc.subject.otherLung tissue
dc.subject.otherTime-varying electrical bioimpedance (EBI)
dc.subject.otherElectronic biopsy
dc.subject.otherMultisine excitation
dc.titleIn vivo electrical bioimpedance characterization of human lung tissue during the bronchoscopy procedure. A feasibility study
dc.typeArticle
dc.subject.lemacEspectroscopis
dc.subject.lemacBiometria
dc.subject.lemacPulmons
dc.contributor.groupUniversitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica
dc.identifier.doi10.1016/j.medengphy.2012.09.004
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac12674712
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorSánchez, B.; Vandersteen, G.; Martín, I.; Castillo, D.; Torrego, A.; Riu, P.; Schoukens, J.; Bragos, R.
local.citation.publicationNameMedical engineering and physics
local.citation.volume35
local.citation.number7
local.citation.startingPage949
local.citation.endingPage957


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple