dc.contributor.authorGómez Pau, Álvaro
dc.contributor.authorBalado Suárez, Luz María
dc.contributor.authorFigueras Pàmies, Joan
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2013-05-16T12:38:28Z
dc.date.created2013
dc.date.issued2013
dc.identifier.citationÁlvaro Gómez-Pau; Balado, L.; Figueras, J. Nondestructive diagnosis of mechanical misalignments in dual axis accelerometers. A: Design, Test, Integration & Packaging of MEMS/MOEMS. "Proceedings of Design, Test, Integration & Packaging of MEMS/MOEMS Conference". Barcelona: 2013.
dc.identifier.urihttp://hdl.handle.net/2117/19295
dc.description.abstractMicroelectromechanical systems production is still an immature technology compared to the classical semiconductor industry. MEMS fabrication and packaging processes may present misalignments which result in an improper placement of the internal microstructures or dies. In this work, the possibilities of diagnosing mechanical misalignments of dual axis IC accelerometers are explored. The used method dynamically correlates the two output signals in orthogonal directions. This leads to a Lissajous composition which is able to manifest the actual level of misalignment. The definition of a metric and its variation rate study allows the diagnosis procedure. Experimental results using a commercial dual axis capacitive accelerometer reveal diagnosis discrepancies as low as 1.1%, therefore showing the viability of the proposal.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura
dc.subject.lcshAccelerometers.
dc.subject.lcshMechanical movements.
dc.titleNondestructive diagnosis of mechanical misalignments in dual axis accelerometers
dc.typeConference report
dc.subject.lemacAceleròmetres
dc.subject.lemacMoviments mecànics -- Anàlisi cinemàtica
dc.contributor.groupUniversitat Politècnica de Catalunya. QINE - Disseny de Baix Consum, Test, Verificació i Circuits Integrats de Seguretat
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac12353917
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorÁlvaro Gómez-Pau; Balado, L.; Figueras, J.
local.citation.contributorDesign, Test, Integration & Packaging of MEMS/MOEMS
local.citation.pubplaceBarcelona
local.citation.publicationNameProceedings of Design, Test, Integration & Packaging of MEMS/MOEMS Conference