Mostra el registre d'ítem simple
Heart rate variability analysis using a seismocardiogram signal
dc.contributor.author | Ramos Castro, Juan José |
dc.contributor.author | Moreno, J. |
dc.contributor.author | Miranda-Vidal, H. |
dc.contributor.author | García González, Miguel Ángel |
dc.contributor.author | Fernández Chimeno, Mireya |
dc.contributor.author | Rodas, G. |
dc.contributor.author | Capdevila, L. |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica |
dc.date.accessioned | 2013-03-05T13:11:10Z |
dc.date.created | 2012 |
dc.date.issued | 2012 |
dc.identifier.citation | Ramos, J. [et al.]. Heart rate variability analysis using a seismocardiogram signal. A: IEEE Engineering in Medicine and Biology Society. "Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2012". San Diego: IEEE, 2012, p. 5642-5645. |
dc.identifier.isbn | 978-1-4244-4119-8 |
dc.identifier.uri | http://hdl.handle.net/2117/18071 |
dc.description.abstract | Seismocardiography is a simple and non invasive method of recording cardiac activity fro m the movements of the body caused by heart pumping. In this preliminary study we use a smartphone to record this acceleration and estimate the heart rate. We compare the heart rate variability parameters from the seismocardi ogram and ECG reference signal. The results show a great similarity and are strongly influenced by the instability in the sampling frequency of the device. The differences between RR series are lower than 10 ms. |
dc.format.extent | 4 p. |
dc.language.iso | eng |
dc.publisher | IEEE |
dc.subject | Àrees temàtiques de la UPC::Enginyeria biomèdica::Electrònica biomèdica |
dc.subject.lcsh | Electrocardiography |
dc.subject.lcsh | Heart -- Diseases -- Diagnosis |
dc.title | Heart rate variability analysis using a seismocardiogram signal |
dc.type | Conference lecture |
dc.subject.lemac | Electrocardiografia |
dc.subject.lemac | Cor -- Malalties -- Diagnòstic |
dc.contributor.group | Universitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica |
dc.identifier.doi | 10.1109/EMBC.2012.6347274 |
dc.description.peerreviewed | Peer Reviewed |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 11151815 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Ramos, J.; Moreno, J.; Miranda-Vidal, H.; Garcia, M.; Fernandez, M.; Rodas, G.; Capdevila, L. |
local.citation.contributor | IEEE Engineering in Medicine and Biology Society |
local.citation.pubplace | San Diego |
local.citation.publicationName | Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2012 |
local.citation.startingPage | 5642 |
local.citation.endingPage | 5645 |