Mostra el registre d'ítem simple

dc.contributor.authorCamós Andreu, Carles
dc.contributor.authorCasas Rius, Joan Ramon
dc.contributor.authorMolins i Borrell, Climent
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de la Construcció
dc.date.accessioned2013-02-12T18:03:45Z
dc.date.created2012
dc.date.issued2012
dc.identifier.citationCamos, C.; Casas, J.; Molins, C. An attempt to the determination of the partial safety factor for SFRC members subjected to bending forces. A: RILEM International Symposium on Fibre Reinforced Concrete. "Eighth RILEM International Symposium on Fibre Reinforced Concrete (BEFIB 2012): challenges and opportunities: Guimarães, Portugal, 19-21 September, 2012". Guimarães: International Union of Laboratories and Experts in Construction Materials, Systems and Structures (RILEM), 2012, p. 1-10.
dc.identifier.isbn978-2-35158-132-2
dc.identifier.urihttp://hdl.handle.net/2117/17687
dc.description.abstractIn the last few years, research on techniques that permit the reduction or even the complete elimination of structural bar reinforcements has been intensified. The addition of steel fibres to the concrete matrix is proven to be an effective way of covering the deficiencies in this material when subjected to tensile stress. However, there still exists uncertainty surrounding some of the basis of design of structural members in ultimate condition. A clear example is the partial safety factor applied to the tensile strength. In this paper, a reliability-based analysis is carried out through the study of a particular application, such as the tunnel lining concrete segments built in an experimental section of the L9 Metro tunnel in Barcelona, solely reinforced with steel fibres. Specimens were extracted from three different segments and tested in tension by using the Barcelona test. Such a representative sample of tensile strength results made possible an assessment of the degree of the existing safety in this particular case by applying the reliability method FORM. The reliability analysis suggested a partial factor equal to 1.77. This would represent a first step to obtain the general material safety factor, which may involve a calibration in a wide range of tunnel segments and afterwards, other structural members and applications of SFRC.
dc.format.extent10 p.
dc.language.isoeng
dc.publisherInternational Union of Laboratories and Experts in Construction Materials, Systems and Structures (RILEM)
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó
dc.subject.lcshFiber-reinforced concrete
dc.subject.othersafety
dc.subject.otherfactor
dc.subject.otherresidual strength
dc.subject.othersegment
dc.subject.otherreliability
dc.subject.otherFORM
dc.titleAn attempt to the determination of the partial safety factor for SFRC members subjected to bending forces
dc.typeConference report
dc.subject.lemacFormigó armat amb fibres
dc.contributor.groupUniversitat Politècnica de Catalunya. TE - Tecnologia d'Estructures
dc.relation.publisherversionhttp://cataleg.upc.edu/record=b1419255~S1*cat
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac11419111
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorCamos, C.; Casas, J.; Molins, C.
local.citation.contributorRILEM International Symposium on Fibre Reinforced Concrete
local.citation.pubplaceGuimarães
local.citation.publicationNameEighth RILEM International Symposium on Fibre Reinforced Concrete (BEFIB 2012): challenges and opportunities: Guimarães, Portugal, 19-21 September, 2012
local.citation.startingPage1
local.citation.endingPage10


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple