Mostra el registre d'ítem simple

dc.contributor.authorLicon Bernal, Edxon Eduardo
dc.contributor.authorCasas Garriga, Sandra
dc.contributor.authorAlcaraz, Aurora
dc.contributor.authorCortina Pallás, José Luís
dc.contributor.authorValderrama Ángel, César Alberto
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Química
dc.date.accessioned2013-01-14T13:46:43Z
dc.date.created2012
dc.date.issued2012
dc.identifier.citationLicon , E. [et al.]. Ammonia removal from water by liquid-liquid membrane contactor under closed loop regime. A: COMSOL Conference. "COMSOL Conference 2012: proceedings: October 10, 2012, Milan, Italy". Milà: 2012, p. 13819 (1)-13819 (7).
dc.identifier.isbn978-0-9839600-7-0
dc.identifier.urihttp://hdl.handle.net/2117/17340
dc.description.abstractAmmonia separation from water by a membrane contactor was simulated on transient state and compared with experimental data. Aqueous low concentrated solution of ammonium with high pH has been pumped inside a hydrophobic hollow fiber (lumen), sulfuric acid solution in the outside part and the feeding solutions are in closed loop configuration. In order to simulate the separation process, the equations were developed considering radial and axial diffusion and convection in the lumen with a well-developed parabolic velocity profile. The model proposed shows minimal deviations when is compared against experimental data. This study shows that the most important parameters to control during the operation are the flow rate and the pH, mainly the last one, due to high dependence in chemical equilibrium of ammonium reaction to ammonia.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Química del medi ambient::Química de l'aigua
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Química inorgànica::Compostos inorgànics
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Química inorgànica::Compostos inorgànics
dc.subject.lcshAmmonia
dc.titleAmmonia removal from water by liquid-liquid membrane contactor under closed loop regime
dc.typeConference report
dc.subject.lemacAmoníac
dc.contributor.groupUniversitat Politècnica de Catalunya. SETRI - Grup de Tècniques de Separació i Tractament de Residus Industrials
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://cataleg.upc.edu/record=b1420968~S1*cat
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac10979693
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorLicon , E.; Casas, S.; Alcaraz, A.; Cortina, J.; Valderrama, C.
local.citation.contributorCOMSOL Conference
local.citation.pubplaceMilà
local.citation.publicationNameCOMSOL Conference 2012: proceedings: October 10, 2012, Milan, Italy
local.citation.startingPage13819 (1)
local.citation.endingPage13819 (7)


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple