Mostra el registre d'ítem simple
Extended-horizon analysis of pressure sensitivities for leak detection in water distribution networks
dc.contributor.author | Casillas Ponce, Myrna Violeta |
dc.contributor.author | Garza Castañón, Luís Eduardo |
dc.contributor.author | Puig Cayuela, Vicenç |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial |
dc.date.accessioned | 2012-10-04T09:47:41Z |
dc.date.created | 2012 |
dc.date.issued | 2012 |
dc.identifier.citation | Casillas, M.; Garza, L.; Puig, V. Extended-horizon analysis of pressure sensitivities for leak detection in water distribution networks. A: IFAC International Symposium on Fault Detection, Supervision and Safety for Technical Processes. "8th SAFEPROCESS 2012. IFAC International Symposium on Fault Detection, Supervision and Safety for Technical Processes". Mexico City: IFAC, 2012, p. 570-575. |
dc.identifier.isbn | 978-80-8075-477-8 |
dc.identifier.uri | http://hdl.handle.net/2117/16633 |
dc.description.abstract | In this paper, a new approach for leak detection in water networks is proposed which considers an extended time horizon analysis of pressure sensitivities. Previous works based on pressure sensitivities analysis were developed by considering time instant evaluation. This fact makes them very sensitive to demand changes and noise in measurements. The proposed approach has been combined with five detection methods: the first is the binarization method, the second, third and fourth are based on the comparison of measured pressure vectors with leak sensitivity matrix using methods of correlation, vector angle and Euclidean distance respectively. And, finally, the fifth is based on the least square optimization method. Another contribution of this paper is the performance comparison between the five detection methods in presence of single leaks in scenarios with noise in measurements and nodal demands. Results showed that in most of the methods effectiveness is high, being the best the vector angle method, with effectiveness higher than 96%. The correlation and optimization method had similar behaviors with effectiveness superior to 90%. Finally, the binarization method is effective only in some scenarios but in presence of noise has a poor performance. |
dc.format.extent | 6 p. |
dc.language.iso | eng |
dc.publisher | IFAC |
dc.subject | Àrees temàtiques de la UPC::Desenvolupament humà i sostenible::Política i gestió ambiental::Gestió de l'aigua |
dc.subject.lcsh | Water-supply |
dc.title | Extended-horizon analysis of pressure sensitivities for leak detection in water distribution networks |
dc.type | Conference report |
dc.subject.lemac | Aigua -- Abastament -- Control |
dc.contributor.group | Universitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control |
dc.rights.access | Restricted access - author's decision |
local.identifier.drac | 10955675 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Casillas, M.; Garza, L.; Puig, V. |
local.citation.contributor | IFAC International Symposium on Fault Detection, Supervision and Safety for Technical Processes |
local.citation.pubplace | Mexico City |
local.citation.publicationName | 8th SAFEPROCESS 2012. IFAC International Symposium on Fault Detection, Supervision and Safety for Technical Processes |
local.citation.startingPage | 570 |
local.citation.endingPage | 575 |