Mostra el registre d'ítem simple

dc.contributor.authorUrresty Betancourt, Julio César
dc.contributor.authorRiba Ruiz, Jordi-Roger
dc.contributor.authorDelgado Prieto, Miquel
dc.contributor.authorRomeral Martínez, José Luis
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica
dc.date.accessioned2012-07-16T14:54:02Z
dc.date.created2012-03-01
dc.date.issued2012-03-01
dc.identifier.citationUrresty, J. [et al.]. Detection of demagnetization faults in surface-mounted permanent magnet synchronous motors by means of the zero-sequence voltage component. "IEEE transactions on energy conversion", 01 Març 2012, vol. 27, núm. 1, p. 42-51.
dc.identifier.issn0885-8969
dc.identifier.urihttp://hdl.handle.net/2117/16262
dc.description.abstractThis paper develops and analyzes an online methodology to detect demagnetization faults in surface-mounted permanent magnet synchronous motors. The proposed methodology, which takes into account the effect of the inverter that feeds the machine, is based on monitoring the zero-sequence voltage component of the stator phase voltages. The theoretical basis of the proposed method has been established. Attributes of the method presented here include simplicity, very low computational burden, and high sensibility. Since the proposed method requires access to the neutral point of the stator windings, it is especially useful when dealing with fault tolerant systems. A simple expression of the zero-sequence voltage component is deduced, which is proposed as a fault indicator parameter. Both simulation and experimental results presented in this paper show the potential of the proposed method to provide helpful and reliable data to carry out an online diagnosis of demagnetization failures in the rotor permanent magnets.
dc.format.extent10 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica::Electrònica de potència
dc.subject.lcshPermanent magnet synchronous motor
dc.subject.lcshZero sequence voltage component
dc.subject.lcshFault diagnosis
dc.titleDetection of demagnetization faults in surface-mounted permanent magnet synchronous motors by means of the zero-sequence voltage component
dc.typeArticle
dc.subject.lemacMotors d'imants permanents
dc.subject.lemacErrors de sistemes (Enginyeria)
dc.contributor.groupUniversitat Politècnica de Catalunya. MCIA - Motion Control and Industrial Applications Research Group
dc.identifier.doi10.1109/TEC.2011.2176127
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=6104129
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac9466036
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorUrresty, J.; Riba, J.; Delgado, M.; Romeral, L.
local.citation.publicationNameIEEE transactions on energy conversion
local.citation.volume27
local.citation.number1
local.citation.startingPage42
local.citation.endingPage51