Mostra el registre d'ítem simple

dc.contributor.authorDomingues de Figueiredo, Antonio
dc.contributor.authorFuente Antequera, Albert de la
dc.contributor.authorAguado de Cea, Antonio
dc.contributor.authorMolins i Borrell, Climent
dc.contributor.authorChama Neto, Pedro Jorge
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de la Construcció
dc.date.accessioned2012-05-09T16:40:01Z
dc.date.available2012-05-09T16:40:01Z
dc.date.created2012-01
dc.date.issued2012-01
dc.identifier.citationde Figueiredo, A.D. [et al.]. Steel fiber reinforced concrete pipes. Part 1: technological analysis of the mechanical behavior. "IBRACON structures and materials journal", Gener 2012, vol. 5, núm. 1, p. 1-11.
dc.identifier.issn1983-4195
dc.identifier.urihttp://hdl.handle.net/2117/15810
dc.description.abstractThis paper is the first part of an extensive work focusing the technological development of steel fiber reinforced concrete pipes (FRCP). Here is presented and discussed the experimental campaign focusing the test procedure and the mechanical behavior obtained for each of the dosages of fiber used. In the second part (“Steel fiber reinforced concrete pipes. Part 2: Numerical model to simulate the crushing test”), the aspects of FRCP numerical modeling are presented and analyzed using the same experimental results in order to be validated. This study was carried out trying to reduce some uncertainties related to FRCP performance and provide a better condition to the use of these components. In this respect, an experimental study was carried out using sewage concrete pipes in full scale as specimens. The diameter of the specimens was 600 mm, and they had a length of 2500 mm. The pipes were reinforced with traditional bars and different contents of steel fibers in order to compare their performance through the crushing test. Two test procedures were used in that sense. In the 1st Series, the diameter displacement was monitored by the use of two LVDTs positioned at both extremities of the pipes. In the 2nd Series, just one LVDT is positioned at the spigot. The results shown a more rigidity response of the pipe during tests when the displacements were measured at the enlarged section of the socket. The fiber reinforcement was very effective, especially when low level of displacement was imposed to the FRCP. At this condition, the steel fibers showed an equivalent performance to superior class pipes made with traditional reinforced. The fiber content of 40 kg/m3 provided a hardening behavior for the FRCP, and could be considered as equivalent to the critical volume in this condition.
dc.format.extent11 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó
dc.subject.lcshPipe, Concrete--Testing
dc.subject.otherfibras de aço
dc.subject.otherensaio de compressão diametral
dc.subject.othernormas
dc.subject.otherconcrete pipes
dc.subject.othersteel fibers
dc.subject.othercrushing test
dc.subject.othermechanical behavior
dc.subject.otherstandards
dc.subject.othertubos de concreto
dc.titleSteel fiber reinforced concrete pipes. Part 1: technological analysis of the mechanical behavior
dc.typeArticle
dc.subject.lemacCanonades de formigó
dc.contributor.groupUniversitat Politècnica de Catalunya. TE - Tecnologia d'Estructures
dc.relation.publisherversionhttp://www.revistas.ibracon.org.br/index.php/riem/article/view/245/255
dc.rights.accessOpen Access
local.identifier.drac9569140
dc.description.versionPostprint (published version)
local.citation.authorde Figueiredo, A.D.; de la Fuente, A.; Aguado, A.; Molins, C.; Chama, P.
local.citation.publicationNameIBRACON structures and materials journal
local.citation.volume5
local.citation.number1
local.citation.startingPage1
local.citation.endingPage11


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple