Mostra el registre d'ítem simple
Experimental validation of radiometric sensitivity in correlation radiometers
dc.contributor.author | Camps Carmona, Adriano José |
dc.contributor.author | Bará Temes, Francisco Javier |
dc.contributor.author | Torres Torres, Francisco |
dc.contributor.author | Corbella Sanahuja, Ignasi |
dc.contributor.author | Monzón Soria, Francisco Jose |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament de Teoria del Senyal i Comunicacions |
dc.date.accessioned | 2008-01-22T12:54:02Z |
dc.date.available | 2008-01-22T12:54:02Z |
dc.date.created | 1998-10-28 |
dc.date.issued | 1998-12-31 |
dc.identifier.citation | Camps, A.; Bara, J.; Torres, F.; Corbella, I.; Monzon, F. Experimental validation of radiometric sensitivity in correlation radiometers. Electronics letters, 1998, vol. 34, núm. 25, p. 2377-2379. |
dc.identifier.issn | 0013-5194 |
dc.identifier.uri | http://hdl.handle.net/2117/1518 |
dc.description.abstract | The prediction of the radiometric sensitivity of correlation radiometers based on the system parameters requires knowledge of the standard deviation of each measurement due to the finite integration time. Theoretical formulations have been experimentally validated showing the dependence of the standard deviation with the measurement and extended for arbitrary over sampling factors. |
dc.format.extent | 2377-2379 |
dc.language.iso | eng |
dc.publisher | IEE-INST ELEC ENG |
dc.subject | Àrees temàtiques de la UPC::Enginyeria de la telecomunicació::Radiocomunicació i exploració electromagnètica::Teledetecció |
dc.subject.lcsh | Radiometers |
dc.subject.lcsh | Signal processing |
dc.subject.lcsh | Correlators |
dc.subject.other | correlation methods |
dc.subject.other | radiometers |
dc.subject.other | sensitivity |
dc.subject.other | correlation radiometer |
dc.subject.other | integration time |
dc.subject.other | radiometric sensitivity |
dc.subject.other | sampling factor |
dc.subject.other | standard deviation |
dc.title | Experimental validation of radiometric sensitivity in correlation radiometers |
dc.type | Article |
dc.subject.lemac | Radiometria |
dc.subject.lemac | Processament de senyals |
dc.subject.lemac | Correladors |
dc.contributor.group | Universitat Politècnica de Catalunya. RSLAB - Grup de Recerca en Teledetecció |
dc.description.peerreviewed | Peer Reviewed |
dc.rights.access | Open Access |
local.identifier.drac | 789681 |
local.personalitzacitacio | true |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [2.491]
-
Articles de revista [618]