Mostra el registre d'ítem simple
Uni and multidirectional wear resistance of different crosslinking degrees in UHMWPE for artificial joints
dc.contributor.author | González-Mora, V. A. |
dc.contributor.author | Hoffmann, Michael |
dc.contributor.author | Stroosnijder, R. |
dc.contributor.author | Espinar, Eduardo |
dc.contributor.author | Llamas, L. M. |
dc.contributor.author | Fernández-Fairén, Mariano |
dc.contributor.author | Gil Mur, Francisco Javier |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament de Ciència dels Materials i Enginyeria Metal·lúrgica |
dc.date.accessioned | 2012-02-15T12:00:04Z |
dc.date.available | 2012-02-15T12:00:04Z |
dc.date.created | 2011 |
dc.date.issued | 2011 |
dc.identifier.citation | González-Mora, V. A. [et al.]. Uni and multidirectional wear resistance of different crosslinking degrees in UHMWPE for artificial joints. "Journal of Biomedical Science and Engineering", 2011, vol. 4, núm. 4, p. 255-263. |
dc.identifier.issn | 1423-0127 |
dc.identifier.uri | http://hdl.handle.net/2117/15152 |
dc.description.abstract | The aim of this work was to study the effect of UHMWPE crosslinking on wear performance. Differently treated UHMWPEs were studied by means of unidirectional and multidirectional wear tests. Unidirectional tests simulate total knee replacement and multidirectional tests simulate total hip replacement movements. The samples tested were observed by optical and scanning electron microscopy in order to determine wear mechanisms that explain the dif-ferent results obtained in the uni- and multidirectional wear tests performed. |
dc.format.extent | 9 p. |
dc.language.iso | eng |
dc.publisher | Springer |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Spain |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Enginyeria dels materials |
dc.subject.lcsh | Polymers in medicine |
dc.subject.lcsh | Artificial joints |
dc.title | Uni and multidirectional wear resistance of different crosslinking degrees in UHMWPE for artificial joints |
dc.type | Article |
dc.subject.lemac | Polímers en medicina |
dc.subject.lemac | Articulacions artificials |
dc.contributor.group | Universitat Politècnica de Catalunya. BBT - Biomaterials, Biomecànica i Enginyeria de Teixits |
dc.identifier.doi | 10.4236/jbise.2011.44035 |
dc.relation.publisherversion | http://www.scirp.org/journal/PaperInformation.aspx?paperID=4688 |
dc.rights.access | Open Access |
local.identifier.drac | 9596116 |
dc.description.version | Postprint (published version) |
local.citation.author | González-Mora, V. A.; Hoffman, M.; Stroosnijder, R.; Espinar, E.; Llamas, L. M.; Fernández-Fairén, M.; Gil, F.J. |
local.citation.publicationName | Journal of Biomedical Science and Engineering |
local.citation.volume | 4 |
local.citation.number | 4 |
local.citation.startingPage | 255 |
local.citation.endingPage | 263 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [960]
-
Articles de revista [438]